Loading ...
Loading ...
Loading ...
38
EN
Cartridge pierced probe and seal washer
Cartridge pierced probe and seal washer maybe damaged when wrong usage or other
reasons, please replace a new one.
1. Firstly, pick out the seal washer with a tiny metal stick (Show as  gure), and take out
Cartridge pierced probe. Be careful not damage other parts of regulator.
2. Install a new cartridge pierced probe in the regulator (leave the sharp end outside
toward), and install the seal washer (Show as  gure). Don’t remove other parts of
regulator in the replacing process.
WARNING
Risk of injury! Remember press the seal circle with empty cartridge
instead of new cartridge, or will cause hazard.
To change beer tube
Please replace the beer tube if beer tube is damaged and cause beer leakage (see
gure 26).
1. Loosen the tube at connection 1 and draw out the tube. Pull down the lock setting,
and draw the tube out.
2. Screw out nut at connection 2, and draw the tube out.
3. Replace a new beer tube, and install the beer tube according with reverse
procedure.
Loading ...
Loading ...
Loading ...