Loading ...
Loading ...
Loading ...
49-3000195 21
ENGLISH
INSTALLATION INSTRUCTIONS
SIDE OR BOTTOM VENTING
Disconnect dryer from electrical supply.
Wear gloves and arm guards.
Close the back opening with cover plate (Kit
WE49X22606).
Failure to do so may result in fire, electrical shock
or lacerations.
SIDE OR BOTTOM VENTING (cont.)
Detach and remove the right, left or bottom knockout
as desired. Remove the screw inside the dryer exhaust
duct and save.
Pull the duct out of the dryer.
Cut the duct as shown and keep portion A.
Reconnect the cut portion (A) of the duct to the blower
housing. Make sure that the shortened duct is aligned
with the tab in the base. Use the screw saved previously
to secure the duct in place through the tab on the
appliance base.
ADDING ELBOW AND DUCT FOR EXHAUST
TO RIGHT OR LEFT SIDE OF CABINET
Preassemble 4” elbow with 4” duct. Wrap duct tape
around joint.
Òñöèõ÷çøæ÷äööèðåïüèïåòúĤõö÷÷ëõòøêë÷ëèöìçè
opening and connect the elbow to the dryer internal
duct.
Be sure not to pull or damage the electrical wires
inside the dryer when inserting the duct.
ADDING A NEW DUCT
Remove
screw
and save
Remove desired
knockout (one only)
Right
Left
Bottom
Portion “A”
Right or left
side exhaust
Fixing hole
Left
Right
Exhaust can be
added to right
or left side
Duct
tape
Right
Left
EXHAUSTING THE DRYER (cont.)
Fixing hole
A
9” (22.86cm)
- Fire Hazard
WARNING
Loading ...
Loading ...
Loading ...