49-3000195 13
ENGLISH
INSTALLATION INSTRUCTIONS
MOBILE OR MANUFACTURED HOME
INSTALLATION
Installation MUST conform to the MANUFACTURED
HOME CONSTRUCTION AND SAFETY STANDARD,
TITLE 24, PART 3280 or STANDARD FOR MOBILE
HOMES CAN/CSA-Z240 MH, or, when such
standards are not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME, ANSI/
NFPA NO. 501B.
The dryer MUST be vented to the outdoors.
The exhaust vent MUST be securely fastened to a
non-combustible portion of the mobile home.
The vent MUST NOT be terminated beneath a
mobile or manufactured home.
The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other
duct, vent or chimney.
DO NOT use sheet metal screws or other fastening
devices which extend into the interior of the exhaust
vent.
Provide an opening with a free area of at least 25
square inches for introduction of outside air into the
dryer room.
See the sections for electrical connection information.
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
The dryer MUST be vented to the outdoors.
Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0” either side
1” front and rear
1” top
The rear of the dryer should face a wall.
Consideration must be given to provide adequate
clearance for installation and service.
Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches of open
area. If the closet contains both a washer and a dryer,
doors must contain a minimum of 120 square inches
of open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE
REAR OF THE DRYER, THE CONFIGURATION OF THE
DUCTING MAY REQUIRE GREATER THAN 3” OF REAR
CLEARANCE.
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and for air
opening are: 0” both sides, 1” rear and 1” top.
The rear of the dryer should face a wall.
Consideration must be given to provide adequate
clearance for installation and service.
- Explosion Hazard
WARNING