Loading ...
Loading ...
Loading ...
18 49-3000195
ENGLISH
INSTALLATION INSTRUCTIONS
EXHAUSTING THE DRYER
TOOLS AND MATERIALS YOU WILL
NEED TO INSTALL EXHAUST DUCT
CONNECTING THE DRYER TO HOUSE
VENT
RIGID METAL TRANSITION DUCT
For best drying performance, a rigid metal transition
duct is recommended.
Rigid metal transition ducts reduce the risk of
crushing and kinking.
UL-LISTED FLEXIBLE METAL CLOTHES DRYER
TRANSITION DUCT
If rigid metal cannot be used, then UL-listed flexible
metal clothes dryer transition duct (Haier Appliances
part – PM08X10085) can be used.
Never install transition duct in walls, ceilings, floors or
other enclosed spaces.
Total length of transition duct should not exceed 8’
(2.4 m).
For many applications, installing elbows at both
the dryer and the wall is highly recommended (see
illustrations in next section). Elbows allow the dryer
to sit close to the wall without kinking and/or crushing
the transition duct, maximizing drying performance.
Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE)
TRANSITION DUCT
In special installations, it may be necessary to
connect the dryer to the home exhaust vent using
flexible metal (foil-type) transition duct. UL–LISTED
universal flexible dryer transition duct (Haier
Appliances parts – PM8X73 or WX8X73) may be
used ONLY in installations where rigid metal or
flexible metal transition ducting cannot be used AND
where a 4” diameter can be maintained throughout
the entire length of the transition duct.
In Canada and the United States, only transition
ducts that comply with “UL 2158A STANDARD FOR
CLOTHES DRYER TRANSITION DUCT” shall be
used.
Avoid resting the duct on sharp objects.
For best drying performance:
1. Slide one end of the duct over the clothes dryer
outlet pipe.
2. Secure the duct with a clamp.
3. With the dryer in its permanent position,
extend the duct to its full length. Allow 2” of
duct to overlap the exhaust pipe. Cut off and
remove excess duct. Keep the duct as straight
as possible for maximum airflow.
4. Secure the duct to the exhaust pipe with the
other clamp.
ʄ Phillips-head
screwdriver
ʄ Duct tape or
duct clamp
ʄ Rigid or UL-listed flexible
metal 4” (10.2 cm) duct
ʄ Drill with 1/8” drill bit
(for bottom venting)
ʄ Hacksaw
ʄ Vent
hood
This dryer MUST be vented to the outdoors.
Use only 4” rigid metal ducting for the home
exhaust duct.
Use only 4" rigid metal, UL-listed flexible metal,
or UL-listed metal foil dryer transition duct to
connect the dryer to the home exhaust.
DO NOT use any plastic to vent the dryer, this
includes the home exhaust duct, dryer transition
duct, or within the dryer.
DO NOT use flexible metal or metal foil ducting
for a home exhaust duct or within the dryer.
DO NOT exhaust into a chimney, kitchen
exhaust, gas vent, wall, ceiling, attic, crawl
space, or concealed space of a building.
DO NOT install a screen in or over the exhaust
duct.
DO NOT install a booster fan in the exhaust duct.
DO NOT use duct longer than specified in the
exhaust length table.
Failure to follow these instructions can result in
death or fire.
VISIT HAIERAPPLIANCES.COM/PARTS
OR IN CANADA VISIT
HAIERCANADA.CA/PARTS
PM8X85
Outdoor exhaust hood
PM08X10085
8’ Flexible metal clothes dryer transition
duct with 2 clamps
WX08X10130
4” Dryer exhaust clamp
WE49X22606
Rear exhaust opening cover, for side or
bottom vented dryers
- Fire Hazard