NEW TECHNOLOGIES
C.L.E.A.N. – Calibrated Level Eliminated Audible Noise –
Allows for accurate setup of an amplifier’s input and output
WITHOUT the need of additional measurement devices.
C.L.E.A.N. IN – Indicates when the input into the amplifier
starts to distort by lighting up RED.
How does it work – Turn the volume level on the source unit
up until the light turns RED, then reduce the volume level
until the light turns OFF. This is the maximum level that the
source unit should be turned up to in order to provide a
distortion free signal into the amplifier.
C.L.E.A.N. OUT – Indicates when the output from the
amplifier starts to distort by lighting up RED.
How does it work – Setup should be performed at the
maximum level of the source unit determined by the
C.L.E.A.N. IN indicator.
Turn the GAIN up until the light turns RED, then turn down
the GAIN until the light turns OFF. This is the maximum level
that the GAIN should be set to in order to provide a distortion
free output from the amplifier.
Auto Remote Turn ON Switch – Utilizes the DC oset of
the source units front LEFT speaker to turn the amplifier ON
and OFF. Turning the switch to the OFF position requires the
connection to the REM input to be connected to a 12 Volt
switched accessory circuit using a 1 Amp fuse or the REM
output from an aermarket head unit.
Note: This only applies to high level inputs.
How does it work – DC oset is the 3-6 Volts coming from
the source unit’s positive speaker lead. This can be tested
using a DMM (Digital Multi-Meter) set to DC voltage by
connecting the meters Positive lead to the front LEFT positive
speaker lead and connecting the negative lead to chassis
ground and turning the source unit ON.