Maytag WGD6600VQ laundry

User Manual - Page 9

For WGD6600VQ.

PDF File Manual, 52 pages, Download pdf file

Loading ...
Loading ...
Loading ...
9
Exhaust
Recommended hood styles are shown here.
4"
(102 mm)
4"
(102 mm)
B
A
A. Louvered hood style
B. Box hood style
The angled hood style (shown here) is acceptable.
4"
(102 mm)
2½"
(64 mm)
C
An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
Exhaust hood must be at least 12" (305 mm) from the ground or
any object that may be in the path of the exhaust (such as
flowers, rocks, or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
Housecleaning problems and health problems.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
A
B
B
C
D
E
F
G
H
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessar
y to connect elbows
H. Exhaust outlet
Standard exhaust installation with rigid metal or flexible
metal vent
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown. Refer
to the manufacturer’s instructions.
A
B
C
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
C. Rear exhaust installation
to left or right side
NOTE: The following kits for close clearance alternate installations
are available for purchase. Please see the “Assistance or Service”
section to order.
Over-the-Top Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch
Part Number 4396011 - 18" (457 mm) to 29" (737 mm)
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (127 mm)
mismatch
Rear exhaust installation to left or right side:
Part Number 49611
Rear Exhaust installation to left side
Part Numbers 8544761 and 8212504
Special provisions for mobil
e home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the m
obile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Loading ...
Loading ...
Loading ...