PROBLEM SOLUTION
The appliance does not switch on when the
ON/OFF button is pressed.
Turn o and unplug the machine, remove the lter cartridge, wait for 20
seconds and then restart the machine. Ensure that the plug on the power
cord is fully inserted into the power socket.
Water or steam issue from the steam nozzle.
In the case of repeated uses, a few drops may come out from the steam
nozzle.
The appliance is working but no liquid is
coming out.
Check that the water container is in the correct position and that the cord
is not jammed between the appliance itself and the water container.
The espresso or coee is not hot enough.
Change the coee temperature setting. Heat the cups by rinsing under
hot water.
The coee is too lightly colored or too weak.
Check that the coee bean container holds coee and that this is owing
correctly.
Avoid using oily, caramelized or avored coee beans.
Reduce the volume of coee using the central dial.
Turn the grind neness dial to the left to obtain more nely ground coee.
Carry out your preparation over two cycles by using the two-cup function.
The coee is poured too slowly or not at all.
Turn the grind neness dial to the right to obtain a more coarsely ground
coee (may depend on the type of coee used).
Carry out one or more rinsing cycles.
Run a damp sponge beneath the coee outlet.
The coee is not creamy.
Turn the grind neness dial to the left to obtain a more nely ground
coee (may depend on the type of coee used).
Change the Claris - Aqua Filter System cartridge (follow the installation
procedure on page 4).
Carry out one or more rinsing cycles.
The appliance has not produced coee.
A problem has been detected during preparation.
The appliance has automatically restarted and is ready for a new cycle.
You have used ground coee instead of coee
beans.
Use your vacuum cleaner to remove the pre-ground coee from the
coee bean container.
The coee grinder makes a strange noise.
There are foreign objects present in the grinder. Contact the KRUPS
Customer Service team.
The grind neness setting dial is dicult to turn.
Only modify the grind neness setting when it is in operation.
There are foreign bodies present in the grinder: contact the KRUPS
Customer Service team.
The steam nozzle of your cappuccino system
seems partially or completely clogged.
Disassemble the nozzle using the dismantling key (41).
Start the cappuccino system rinsing cycle to remove the remainder of the
deposits.
Clean the steam nozzle and ensure that the opening of the nozzle is not
obstructed by remains of milk or limescale. Use the cleaning needle if
necessary (42).
The cappuccino system does not pull in the
milk.
The cappuccino system makes little or no froth.
Check that the appliance is correctly assembled.
Ensure that the setting button is in the CAPPUCCINO position.
Ensure that the steam nozzle is not blocked.
Ensure that the air nozzle is in place and correctly assembled. The air
nozzle (38) may be blocked; leave it to soak in hot water and some dish
detergent, and then rinse prior to reassembly.
Ensure that the exible pipe is not blocked or twisted and that it is
properly inserted into the cassette to avoid any air leak.
Ensure the milk suction pipe is fully immersed in the milk.
Rinse and clean the system (see corresponding sections).
For milk-based preparations: we recommend that you use very fresh,
very cold pasteurized or UHT milk, recently opened. Unpasteurized milk
does not produce the best results. It is also recommended that you use a
cold container.
After having washed the coee drawer
(1)
,
the warning message is still displayed on the
screen.
Remove the drawer, wait for six seconds, then replace it. Wipe clean the
area where the coee drawer
(1)
sits and ensure the coee drawer
(1)
is
correctly installed.
12