•Before making the connection, make sure that the installation is
protected by a suitable fuse, see table, and that it is fitted with
wires of a large enough section to supply the appliance normally.
•Open the cover in the following sequence;
5.3 WIRING AND SAFETY OF THE BUILT-IN
COMBINED OVEN
Figure 1 Figure 1 Figure 1
• Unscrew the cable clamp “1”,
• Find the two tabs located on the sides,
Put the blade of a flat screw-driver in front of each tab “2” e “3”,
push in and press,
• Remove the cover.
To release the power supplying cord.
Remove the screws retaining the terminal block which contains
the shunt bars and the conductors of the supply cord,
• Pull out the supply cord.
•Operations to be carried out to make a mew connection:
-Choose the power supply cable in accordance with the
recommendations in the table.
-Pass the power supply cable in to the clamp.
-Strip the end of each conductor of the supply
cord on a 10 mm length, by taking in account
the requested length of the cord for the
connection to the terminal block.
-According to the installation and with the help
of shunt bars which you should have recovered
in the
first operation, fix the conductor as
shown on the chart.
-Fix the cover.
-Screw the cable clamp.
Note: make sure the terminal board screws are
tight.
5.4 VITROCERAMIC HOB WITHOUT
CONTROL KNOB
550x10
22 mini
Bult-in oven "apertures" : Refer to the
instructon booklet concerned.
OVEN
HOB
Connection to the electrical circuiton glassceramic
hobshDOO
be
madeRQO\viatheoven.
To proceed with the connection, it is necessary to joint
male connectors 1 and 2 of the hob with the
“female” connectors 3 of the oven or of the control panel.
INSTALLATION WITH OVEN
This connection can be made before or after the oven is
screwed into place.
Figure 1
Figure 1
Figure 1
09 GB
LAY OUT
"1-3-5"
LAY OUT
"2-4"
MONOPHASE or TWO PHASES 220-240 V
~
Cable
HO5V2V2F
Cable
HO5V2V2F
Cable
HO5V2V2F
3x4 mm
2
3x4 mm
2
4x1,5 mm
2
4x1,5 mm
2
4x1,5 mm
2
4x1,5 mm
2
THREE PHASES 220-240 V3~
THREE PHASES 380-415 V2N~
N
=
Neutral
PE
=
EarthL1 / L2 / L3 = Phase
Turn over the oven / hob, glass side against the work top, taking
care to protect the glass.
SHUNT
1
1
PE
L3 L2
1
1
L3
L2
L1
380-415 V3 N
~
220-240 V
~
220-240 V3
~
220-240 V2
~