Luxpower SNA4000 WPV Eco Hybrid

User Manual - Page 18

For SNA4000 WPV.

PDF File Manual, 20 pages, Read Online | Download pdf file

SNA4000 WPV photo
Loading ...
Loading ...
Loading ...
5. Monitor System for Off grid
Local Monitor
BA 19310175 9532004127
Solar Yielding
0.0 kWh
300.8 kWh
Battery Discharging
0.0 kWh
Today Discharging
Total Discharging
50.1 kWh
+
Feed-in Energy
0.0 kWh
Today Export
Total Export
77.1 kWh
Consumption
0.0 kWh
Today Usage
Total Usage
255.3 kWh
PV Power
0 W
Consumption
0 W
Backup Power(EPS)
Standby
Battery Power
0 W
Battery Level(SOC)
0 W
0 W
Notice
Overview Set
Users can use wifi dongle / WLAN dongle / 4G dongle (Avaiblable from 2021 March for some countries) to
monitor the energy storage system, The monitor website is: server.luxpowertek.com
1. Wifi Quick Guidance
Quick guidance for setting password for wifi module, the paper is also available in the wifi box
2.Monitor system setup for Distributors and Monitor system setup for endusers, Monitor system registration,
wifi password setting, and wifi local monitor and setting
3.Lux_Monitor_UI_Introduction
Introduction of monitor interface
4. WebsiteSettingGuidance
Introduction of website settings for offgrid inverter
Please download the introduction of guidance by website: https://www.luxpowertek.com/download/
Document Reference:
The APP is also available in the google play and apple APP store(Scan two code bar to download the APP).
INVERTER MODEL SNA5000WPV/SNA4000WPV/SNA3000WPV
Input Voltage Waveform
Sinusoidal (utility or generator)
Nominal Input Voltage
230Vac
Low Loss Voltage
170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage
180Vac±7V (UPS); 100Va7V (Appliances)
High Loss Voltage
280Vac±7V
High Loss Return Voltage
270Vac±7V
Max AC Input Voltage
280Vac
Nominal Input Frequency
50Hz / 60Hz (Auto detection)
Output Short Circuit Protection
Circuit Breaker protect when GridOn Bypass
Transfer Time
<20ms @ Single <30ms @ Parallel
Output power derating: When AC input voltage
drops to 170V, the output power will be derated.
Output Power Rated Power 20% Power
Table 1 Line Mode Specifications
6. Specifications
Software protect when GridOff discharge
31
32
Charge power derating:
When AC input voltage drops to 170V depending
on models, the charge power will be derated.
Output power derating: When AC input voltage
drops to 200V, the output power will be derated.
Max inv curren: 25A;
Max inv Power: 5kW;
Output Power
Rated Power
50% Power
90V
170V
280V
Input Voltage
Rated Output Power
5KVA/5KW
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
208Vac/220Vac/230Vac/240Va5%
Output Frequency
50Hz / 60Hz
Peak Efficiency
93%
Overload Protection
5s@≥150% load; 10s@110%~150% load
Surge Capacity
2* rated power within 5 seconds
Table 2 Inverter Mode Specifications
4KVA/4KW
3KVA/3KW
Loading ...