Luxpower SNA4000 WPV Eco Hybrid

User Manual - Page 16

For SNA4000 WPV.

PDF File Manual, 20 pages, Read Online | Download pdf file

SNA4000 WPV photo
Loading ...
Loading ...
Loading ...
AcIn: AC voltage
range setting
Unity AC Input voltage range :
90Vac~280Vac
AC Output voltage range :
170Vac~280Vac
13
Eod:
Discharge end
voltage or soc with
grid, depend on
TEOd
Setting range:
VOLT: Cut off Volt-56V
Default: 42V
12
SOC: Cut off SOC -90
Default: 15%
CutOFF:
Cut off Voltage
or SOC, depend
on TEOd
Setting range:
VOLT: 40.0-OnGrid EOD Volt
Default: 42V
11
SOC: 0-OnGrid EOD SOC
Default: 15%
Eod:
Discharge end
voltage or soc with
grid, depend on
TEOd
Setting range:
VOLT: Cut off Volt-56V
Default: 42V
12
SOC: Cut off SOC -90
Default: 15%
27
28
Hybrid enable/
disable
Setting Range:
Hybrid Disable (default)
Hybrid Enable
16
Utility source
(AC Input) to take
Load time setting
Setting time of 1 start:
Range:00:00~23:59
Default:00:00~00:00
Setting time of 1 end:
Range:00:00~23:59
Default:00:00~00:00
Similar to set time 2 and time3
15
st art
en d
st art
st art
AC charge setting
(The setting process
must enable the AC
charging function,
confirm the full
battery SOC value,
and set the
confirmation time
period 1, 2, 3 to
truly complete the
AC charging
function setting)
AC Charge function:
Disable(Default)
Enable
(Touch “Enter” button to
set ac charge parameter )
Setting AC Charge current:
30A(Default)
40A / 50A / 60A
Setting AC Charge to battery SOC:
Range:0%~100%
Default:100%
Setting AC Charge time of 1 start:
Range:00:00~23:59
Default:00:00~00:00
Setting AC Charge time of 1 end:
Range:00:00~23:59
Default:00:00~00:00
Similar to set time2 and time3