12
13
SECTION 4
The Brewer should be de-scaled every 6
months to ensure optimal performance. It is
possible for calcium deposits to build up faster,
making it necessary to de-scale more often.
This Brewer is equipped with sensors to detect
when scale buildup is interfering with the
performance of the Brewer. When this is
detected, the De-Scale indicator will illuminate
on the LCD Message Center.
You should de-scale if this indicator is lit on
the LCD Message Center. Properly follow the
de-scaling procedure described below.
De-Scaling
a. PREPARE
Step 1: Make sure you have at least 48
ounces of undiluted white vinegar on hand.
You will also need an empty sink and a
ceramic cup (do not use a paper cup.)
Step 2: Make sure you have a ceramic cup
(do not use a paper cup.)
Step 3: Empty the water in the Water Reservoir.
b. FILL AND CLEAN
Step 1: Pour the vinegar into the Water
Reservoir and fill it to the top edge of the
clear viewing area.
Step 2: Place a ceramic cup in the Drip Tray
and run a brew cycle. DO NOT USE A
K-CUP…just press the Large Cup
Button. Pour the contents of the cup
into the sink.
Step 3: Repeat the brew process until the
Water Reservoir is empty, pouring the
contents of the cup into the sink after each
cycle. Remember to open and close the lid
between each cycle.
Step 4: Rinse the Water Reservoir
thoroughly and fill with fresh water.
Step 5: Now let the Brewer stand for
4 hours while still on.
c. RINSE
Step 1: Ensure the Water Reservoir is filled
with fresh water.
Step 2: Place a ceramic cup on the Drip Tray
and run a regular brew cycle. Pour the
contents of the cup into the sink.
Step 3: Repeat brew process until the Water
Reservoir is empty.
Step 4: You may need to perform additional
rinse cycles if you notice any residual taste.
Storage
Empty the Water Reservoir before storing and
take care to ensure that you store your Brewer
in a safe and frost free environment. If you store
the Brewer in a cold environment, you run the
risk of water freezing inside the Brewer and
causing damage. When you prepare to use it
after storage, we recommend rinsing the Water
Reservoir with fresh water and running three
cleansing brews.
If you plan to move your Brewer to a different
location, turn the Brewer off, unplug it and
empty the Water Reservoir.
TROUBLESHOOTING
SITUATION SOLUTION
Brewer will not brew
when used for the
first time
• Check to be sure that it is plugged in securely.
• Plug into a different outlet.
• Reset circuit breaker if necessary.
• Make sure that the Power Button has been turned on and the
green light shows.
• The Brewer must be primed for use by filling the internal hot
water tank before the first brew. ‘PRIME’ will be displayed on the
LCD Message Center (refer to page 6).
Brewer will not brew
• After placing the K-Cup in the K-Cup Holder, make sure that
the Handle is pushed down securely and the LCD Message
Center changes from ‘READY’ to ‘BREW’, then press either
the Large Cup or Small Cup Button.
• If the LCD Message Center indicates ‘ADD WATER’, add water
to Water Reservoir or make sure the Water Reservoir is seated
properly in its base.
• If the LCD Message Center indicates ‘ADD WATER’ even
after refilling, contact Customer Service at
1-866-901-BREW (2739).
Brewing a partial cup
• The Exit Needle may be clogged. (refer to page 11).
• Clean K-Cup Holder if necessary and rinse under faucet.
(refer to page 11).
• The Water Reservoir may have been removed during brewing.
Replace the Water Reservoir and perform a cleansing brew.
• If the LCD Message Center indicates ‘De-Scale’, descale the Brewer
(refer to page 11).
• If you have repeated the decale procedure on your brewer two times
and the message is still displayed, contact Customer Service at
1-866-901-BREW (2739).
Brewer Does Not
Have Power
The time is not
displayed on the
LCD Message Center
• The time will not be displayed on the LCD unless you have set it.
To set the clock, follow the procedure on Page 10.
• If power is interrupted to the Brewer, you will need to set the
clock again using the procedure on page 10.
6:15
AM
MENU
DE-SCALE
NOTE: If the De-scale indicator on the
LCD Message Center remains on after
completing the procedure, repeat the
de-scaling procedure above.
NOTE: The Brewer will continue to function
even when the De-scale indicator is lit.
However, if you do not de-scale soon
after the indicator is lit, continued scale
build up could damage the Brewer. If this
occurs, the De-Scale indicator will begin
to blink to alert you to the potential damage to
the Brewer if you do not de-scale immediately.
If any problems persist, contact Customer Service at 1-866-901-BREW (2739).