45
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
Whenplacingtheaugerassemblyintheunit,alwaystightenthefouraugerbearingboltsina
diagonal(crisscross)patterntoensurethebearingsandshaftsarealignedproperly.
Remembertoinstalltheaugershelfsupport,placingthetwobottomboltsthroughtheshelf
andtheaugerbearing.
NOTE:Followthesameproceduretoworkonthebottomauger,withtheexceptionthatthe
pelletsdonotnecessarilyhavetoberemovedfromthehopper.
Visityoutube.com/heatredefinedfordetailedservice‘howto’videos.
Combustion(Exhaust)Blower
Beforebeginninganycomponentreplacement,becertaintheunitisunpluggedand
thoroughlycooleddown.
Disconnectthepelletventpipesothatthecombustionblowermaybeaccessed.
Removetheleftsideaccesspanel,using a5/16”wrench..
Removethebackpaneloftheunit,usinga
5/16”wrench.
Disconnectthepowerleadstothecombustionblower.
Removeall (5) screwswhichholdtheexhaustblowertotheexhaustblowertube.Oncethe
screwshavebeenremoved,theblowercanbeliftedupandoutofthestove.
Replacethecombustionblowergasketeach
timeyouremovetheblowerfromthestove
(Part#PUCBMG).
Removethegasketwithaputtyknife,andinstallthenewgasketby
applyingadhesivetotheblowerflangeandinstallingthenewgasket(instructionsand
adhesiveareprovidedwiththegasket).
Reinstallationistheexactoppositeofthestepsabove.
Visityoutube.com/heatredefinedfordetailedservice‘howto’videos.