Gas connection
46
The gas connection is set up for natural
gas (see label on the appliance).
Connection to the appliance
The gas connection has a ¹/₂" conical
thread. There are two possibilities for
connection:
fixed connection
flexible hose class B or D which
complies with AS/NZS 1869 and
must be certified. The minimum
innerØ must be 10mm and the
maximum length 1.2m.
Setting the gas pressure
The gas pressure must be set by the
approved gas fitter as shown on the
data plate:
Natural gas 1.0 kPa
After installation, the test must be
carried out by an approved gas fitter
to confirm the correct gas pressure.
The gas pressure must be set with all
of the burners operating at maximum
setting.
The gas regulator is only included with
appliances which are set up for
connection to natural gas.
a
a
Pressure Test Point
Loosen the screw in the test point
until it is free in its housing. The
screw is retained in this position.
Connect the hose from the pressure
gauge.
Light all of the burners.
Test and ensure that the gas pressure
at the test point is 1.0 kPa.
Disconnect gauge and screw in the
test point screw.
Checking operation
Check all gas fittings for leaks.
Ignite all burners to check that they
are operating correctly.
The flame must not go out on the
lowest setting, or when the control is
turned quickly from the highest to the
lowest setting.
On the highest setting, the flame
must have a distinctive and visible
core.