Remove LP burner orifice. Replace Red marked
LP gas burner orifice with the main burner orifice
stamped NG supplied in the bag.
Slide the notch on the cone onto the flat part of
the burner tube, then turn the cone upright and
slide the flat end of the burner supply tube into
the closed slot.
Remove the compression nut from the pilot
burner assembly using the 3/8" and 5/16" wrench
to expose pilot burner orifice. Remove natural
gas pilot burner orifice and replace with Yellow
marked LP pilot burner orifice supplied in the
package. Replace the compression nut on pilot
burner assembly and tighten the nut.
Replace Red marked LP main burner with
main burner (Natural gas) supplied in the package.
Reinstall the two #6 x 3/8" long Phillips head
screws. Screw the pilot burner assembly to the
burner bracket using the Phillips head screw
removed on step 7.
Remove the gasket from inner door. Clean the
metal surfaces to assure good adhesion of new
gasket (supplied in bag) to the inner door. Align
screw holes of new gasket with holes on inner
door and press gasket firmly in place.
Reinstall entire inner door assembly to the heater.
Ensure the speed clips are in place and the
gasket is fully sealed. Attach inner door loosely
to the heater using four #20 TORX screws.
Reconnect and tighten burner supply, pilot tube
and thermocouple at the thermostat. Handle tubes
carefully to avoid damaging them. DO NOT
over-tighten or cross-thread the connections. Now
tighten the four #20 TORX screws to secure the
inner door firmly to the heater. Reconnect the
piezo wire to the piezo ignitor striker connection.
Attach green CAUTION label from the bag to the
outside of the water heater near the gas control.
Label should be signed by qualified installer or
service organization
Return the unused parts to the bag for possible
future conversions. Return the bag and this Use
and Care manual to the plastic bag attached to the
water heater.
Install outer jacket door to heater.
Turn manual gas shut off valve to the ON
position to start gas flow to the thermostat. Leak
test all gas connections and caps with soap/water
solution. Bubbles indicate a leak. Make certain
all leaks have been repaired and the outer jacket
door has been replaced.
8
Follow lighting instructions on page 15 of the
manual to start the water heater.
Natural/ LowNox Gas Burner LP Burner
Red
marked
color
Pilot supply tube
Burner supply
Thermocouple
Natural Gas Pilot burner
orifice
Jacket door
Conversion instructions—LP Gas to Natural Gas
Cone
Burner supply tube
Burner
orifice
Burner supply
tube
Burner
Main burner orifice
(stamped NG)
Loading ...
Loading ...