Installation
60
The nozzles not provided are available at Authorised Service Centres.
8 Natural gas G2.350 – 13 mbar AUX SR RR R UR3
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.90
Nozzle diameter (1/100 mm)
100 126 160 170 200
Reduced flow rate (W)
400 450 650 750 1400
Primary air (mm)
1.51.511.53
9 LPG G30/31 - 30/37 mbar AUX SR RR R UR3
Rated heating capacity (kW)
1.0 1.70 2.60 3.10 3.90
Nozzle diameter (1/100 mm)
48 62 76 85 95
Reduced flow rate (W)
400 450 650 750 1400
Primary air (mm)
222104
Rated flow rate G30 (g/h)
73 124 189 225 284
Rated flow rate G31 (g/h)
71 121 186 221 279
10 LPG G30/31 - 37 mbar AUX SR RR R UR3
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.90
Nozzle diameter (1/100 mm)
48 60 73 80 89
Reduced flow rate (W)
400 450 650 750 1600
Primary air (mm)
22244
Rated flow rate G30 (g/h)
80 124 189 225 284
Rated flow rate G31 (g/h)
79 121 186 221 279
11 LPG G30/31 - 50 mbar AUX SR RR R UR3
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.90
Nozzle diameter (1/100 mm)
42 54 67 73 82
Reduced flow rate (W)
400 450 650 750 1400
Primary air (mm)
1.5 2 1.5 2 2.5
Rated flow rate G30 (g/h)
80 124 189 225 284
Rated flow rate G31 (g/h)
79 121 186 221 279
12 Town gas G110 – 8 mbar AUX SR RR R UR3
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.70
Nozzle diameter (1/100 mm)
132 165 210 240 290
Reduced flow rate (W)
400 450 650 750 1400
Primary air (mm)
1.51 11.52
13 Town gas G120 – 8 mbar AUX SR RR R UR3
Rated heating capacity (kW)
1.10 1.70 2.60 3.0 3.90
Nozzle diameter (1/100 mm)
126 160 200 230 270
Reduced flow rate (W)
400 450 650 750 1400
Primary air (mm)
1.51 11.52