Rinnai Australia 12 Operation Manual
UNIVERSAL WATER CONTROLLERS
HOW TO USE TWO OR MORE UNIVERSAL WATER CONTROLLERS
TURNING ON THE WATER CONTROLLERS
If the controllers are switched off (No digits displayed in the digital
monitor window) press the On/Off button once at any controller.
The ON indicator on the desired controller will illuminate,
indicating that the hot water unit will be ready to supply hot water
once a hot water tap is opened.
TRANSFERRING PRIORITY
An illuminated On/Off indicator confirms that the desired controller
is in control of the water delivery temperature, if the On/Off
indicator is not illuminated press the TRANSFER button once.
The On/Off indicator on the controller will now illuminate indicating
that hot water temperature control has now been transferred to
this controller and that the hot water unit will be ready to supply hot
water once a hot water tap is opened.
ADJUSTING TEMPERATURE
Select the desired temperature using the 'Hot water temp' or
buttons until the required temperature is displayed on the
digital monitor.
To operate the hot water unit, open any hot water tap. This will
automatically light the burner providing hot water. The water
heater ‘In Use’ indicator will illuminate on the water controller.
Once the hot water is running, if the set temperature is either too
hot or cold press the 'Hot water temp' or buttons until the
desired temperature is reached.
CHECK WATER TEMPERATURE BEFORE USE.
A parent or carer should always check the temperature before a child is placed
in contact with hot water, see page 4.
Whilst hot water outlets are open the set temperature may be lowered. However
they cannot then be raised above 43°C. In addition transfer of 'priority' between
controllers is not possible. These are safety features.
Temperatures higher than 50ºC should not be able to be selected on controllers
installed in bathrooms, ensuites or toilets. This is to help reduce the risk of burns
from hot water. If this is not the case, the controllers have been incorrectly
installed. CONTACT YOUR INSTALLER.
The temperature of outgoing hot water is constantly monitored by a built-in
sensor. If the temperature of the outgoing hot water rises to more than 3°C above
the selected temperature shown on the digital monitor or the pre-set limit when
water controllers are not fitted, the burner will automatically go out. The ‘in use’
indicator will also go out. The burner will ignite again once the outgoing hot
water temperature falls to that shown on the digital monitor (or the pre-set limit
of the appliance).
HOTHOT
COLDCOLD
ON!ON!
CAUTION
NOTE