Maintenance
English 47
Pump lter
It is advisable to clean the pump lter 5 or 6 times a year to prevent its clogging. A
clogged pump lter may reduce the bubble effect.
A
1. Turn off the washer, and unplug the
power cord.
2. Drain the remaining water inside
the drum. See the “Emergency drain
section on page 45.
3. Gently press the top area of the lter
cover to open.
4. Turn the pump lter knob (A) to the left,
and drain off the remaining water.
5. Clean the pump lter using a soft brush.
Make sure the drain pump propeller
inside the lter is not clogged.
6. Reinsert the pump lter, and then turn
the lter knob to the right.
7. Close the lter cover.
NOTE
Some pump lters feature a safety
knob that is designed to prevent
children from accidentally opening the
lter compartment. To open the safety
knob of the pump lter, push in and
turn it counterclockwise. The spring
mechanism of the safety knob helps
open the lter.
To close the safety knob of the pump
lter, turn it clockwise. The spring
makes a rattling sound, which is normal.
NOTE
If the pump lter is clogged, the “5C” information code appears on the washer’s display
screen.