Loading ...
Loading ...
Loading ...
11
INSTALLATION
EN
Dimensions and Clearances
Too small of a distance from adjacent items may result in the degradation of freezing capability and
increased electricity costs. Allow over 50 mm of clearance from each adjacent wall when installing
the appliance.
A
C
B
EFG
D
H
EFG
D
H
Type A Type B
Pocket Handle Bar Handle Pocket Handle Bar Handle
Size [mm]
A 595 595 595 595 595 595 595 595
B 1860 2030 1860 2030 1860 2030 1860 2030
C 675 675 712 712 682 682 718 718
D 9 9 9 9 15 15 15 15
E 667 667 667 667 667 667 667 667
F - - 703 703 - - 703 703
G 1124 1124 1124 1124 1130 1130 1130 1130
H 995 995 995 995 995 995 995 995
Ambient Temperature
• The appliance is designed to operate within a limited range of ambient temperatures, depending on
the climate zone.
• The internal temperature could be affected by the location of the appliance, the ambient
temperature, the frequency of door opening and so on.
• The climate class can be found on the rating label.
Climate Class Ambient Temperature Range ºC
SN (Extended Temperate) +10 - +32
N (Temperate) +16 - +32
ST (Subtropical) +16 - +38
T (Tropical) +16 - +43 / +10 - +43*
*Australia, India, Kenya
NOTE
The appliances rated from SN to T are intended to be used at an ambient temperature between
10 ºC and 43 ºC.
Type A Type B