Installation instructions
Electrical connection (non-Canada) - 4 wire cord
4-wire receptacle
(NEMA type 14-30R)
Neutral
WHITE wire)
1 Turn off power supply to outlet.
2 Remove the screw securing the terminal block access
cover in the lower corner on the back of the dryer.
3 Install a UL-approved strain relief according to the
power cord/strain relief manufacturer's instructions
in the power cord entry hole below the access panel.
At this time, the strain relief should be loosely in
place.
4 Thread an UNPLUGGED_ UL-approved, 30 amp.
power cord_ NEMA 14-30 type ST or SRDT0 through
the strain relief.
5 Disconnect the dryer internal ground wire (WHITE)
from the ground screw (GREEN) next to the terminal
block.
6 Attach the power cord ground wire (GREEN) to the
ground screw (GREEN) next to the terminal block.
Tighten the screw securely.
7 Move the dryer internal ground wire (WHITE) to the
terminal block and attach it along with the neutral
(WHITE) power cord wire conductor to the cente b
SILVER colored terminal on the terminal block.
Tighten the screw securely.
8 Attach the RED and BLACK power cord conductors
to the oute b BRASS colored terminals on the terminal
block. Tighten both screws securely,
GREEN
ground screw
\
"\ \
\ \
\
I GREEN
ground_
Move internal ground
(WHITE) wire to neutral
(silver) terminal for
4-wire system
BLACK
or RED
power wire
Neutral
WHITE
neutral wire
BLACK
or RED
power wire
9 Follow manufacturer's guidelines for firmly securing
the strain relief and power cord.
10 Reinstall the terminal block cover.