General
This appliance should only be connected by authorised personnel.
This appliance should be installed according to the requirements of the
local authority.
Caution!
The type of gas and the country for which the appliance has been
designed are indicated on the application identification card.
Please contact the ASKO service department if installation or
operational faults occur during installation.
This is a category 3 appliance.
Gas connection
The gas connection must comply with national and local
regulations.
The hotplate can be connected with rigid pipe as specified in
AS/NZS 5601.1 table 3.1.
The hotplate can be connected with a Flexible Hose, which
complies with AS/NZS 1869, 10 mm ID, class B or D, no more than
1.2 m long and in accordance with AS/NZS 5601.1. Ensure that
the Hose does not contact the hot surfaces of the hotplate, oven,
dishwasher or other appliance that may be installed underneath or
next to the hotplate.
Warning!
Ensure that the hose assembly is restrained from accidental
contact with the flue or flue outlet of an underbench oven. The
hose should not be subjected to abrasion, kinking or permanent
deformation and should be able to be inspected along its entire
length. Unions compatible with the hose fittings must be used and
connections tested for gas leaks. The supply connection point shall
be accessible with the appliance installed.
In all cases the connection tap for the appliance must be positioned
such that it is easily accessible.
Before using the appliance for the first time check the connections
using water and washing-up liquid to ensure that there are no gas
leaks.