Beurer SI 40

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Other Documents
  • Instruction for use SI 40 German DE, English EN, French FR, Spanish ES, Italian IT, Polish PL, Turkish TR, Russian RU, Dutch NL, Swedish SV, Norwegian NO, Finnish FI, Danish DA - (English) Download
Specification
  • Data sheet SI 40 English EN - (English) Download
SI 40 photo

Instruction for use SI 40 English EN

This is the main product document for model SI 40. Additionally, the document applies to other Beurer models: 4211125601324, 60132

The file format is pdf, 8 pages, you can download this manual here .

background
SI 40
EN Steam vaporiser
Instructions for use
background
2
2
3
7
5
6
11
12
1
8
9
10
4
A B
G
C D
E F
background
3
Contents
1. INCLUDED IN DELIVERY
Check that the exterior of the cardboard delivery packaging is
intact and make sure that all contents are present. Before use,
ensure that there is no visible damage to the device or acces-
sories and that all packaging material has been removed. If you
have any doubts, do not use the device and contact your retailer
or the specified Customer Service address.
Steam vaporiser
Aroma mask
Facial sauna mask
These instructions for use
2. SIGNS AND SYMBOLS
The following symbols are used on the device, in these instruc-
tions for use, on the packaging and on the type plate for the de-
vice:
WARNING
Indicates a potentially impending danger. If it is not avoided,
there is a risk of death or serious injury.
CAUTION
Indicates a potentially impending danger. If it is not avoided,
slight or minor injuries may result.
NOTICE
Indicates a potentially harmful situation. If it is not avoided, the
system or something in its vicinity may be damaged.
Observe the instructions for use
Protection class 2 device
Manufacturer
I On
O O
IP21
Protected against foreign objects equal to or greater
than 12.5 mm in diameter and against vertically falling
drops of water
This product satisfies the requirements of the appli-
cable European and national directives.
B
A
Marking to identify the packaging material.
A = Material code, B = Material number:
1-7 = Plastics, 20-22 = Paper and cardboard
Serial number
Separate the product and packaging elements and
dispose of them in accordance with local regulations.
United Kingdom Conformity Assessed Mark
Item number
Type number
Temperature limit
Humidity limitation
1. Included in delivery ......................................................... 3
2. Signs and symbols .......................................................... 3
3. Intended use .................................................................... 4
4. Warnings and safety notes .............................................. 4
5. Device description ........................................................... 5
6. Initial use ......................................................................... 5
7. Usage .............................................................................. 6
8. Cleaning and maintenance .............................................. 6
9. Accessories and replacement parts ................................ 7
10. What if there are problems? .......................................... 7
11. Disposal ......................................................................... 7
12. Technical specifications ................................................ 7
13. Warranty / service ........................................................... 7
ENGLISH
Read these instructions for use carefully and keep them for later use. Make them accessible to other users and
note the information they contain.
background
4
3. INTENDED USE
This device is specifically designed to generate steam using va-
porisation, in order to humidify your skin and the ambient air. You
can also use it with additives, such as essential oils.
Once it has been properly prepared, the device can be used
again. Preparation involves exchanging the masks and disinfec-
ting the surface of the device using a conventional disinfectant.
Please note that the masks should always be exchanged if the
device is used by more than one person. We recommend that
you replace the mask after one year.
4. WARNINGS AND SAFETY NOTES
WARNING
Before use, ensure that there is no visible damage to the de-
vice or accessories. If you have any doubts, do not use the
device and contact your retailer or the specified Customer
Service address.
In the event of device faults, please see Chapter “Trouble-
shooting”.
This is not a medical device. Always consult your doctor if you
require medical treatment.
This device may be used by children over the age of 8 and
by people with reduced physical, sensory or mental skills or
alack of experience or knowledge, provided that they are su-
pervised or have been instructed on how to use the device
safely, and are fully aware of the consequent risks of use.
Children must not play with the device.
Please observe the general hygiene measures when using the
steam vaporiser.
If the device does not work properly, or you feel unwell or
experience pain, stop using it immediately.
Do not position your face too close to the mask, otherwise the
hot steam could cause burn injuries. Close your eyes during
the treatment and protect heat-sensitive zones.
Never open the device (remove the cover, unscrew the lid)
while it is in operation. Allow the device to cool down first.
Otherwise, you may get burnt.
Do not operate the device in the presence of flammable gases
or if there is ahigh oxygen concentration.
Never leave the device unattended while in use.
The device must be switched o and the plug pulled out befo-
re every cleaning and/or maintenance procedure.
Keep packaging material away from children (risk of suo-
cation).
To avoid the risk of entanglement and strangulation, store the
cable out of the reach of small children.
Do not use any additional parts that are not recommended by
the manufacturer.
The device must only be connected to the mains voltage that
is specified on the type plate.
Never submerge the device in water and do not use it in the
bathroom. Under no circumstances may liquid enter the de-
vice.
Protect the device from heavy impact.
Never touch the mains cable with wet hands, as you could
get an electric shock.
Do not pull the mains plug out of the socket using the mains
cable.
Do not crush or bend the mains cable, pull it over sharp-
edged objects or leave it dangling down, and protect it from
sources of heat.
We recommend that the power cable is completely unrolled to
avoid dangerous overheating.
If the mains connection cable of this device is damaged, it
must be replaced by the manufacturer, its customer service
department or asimilarly qualified person to avoid any risks.
If the device is opened, there is arisk of electric shock. Dis-
connection from the power supply network is only guaranteed
if the mains plug is unplugged.
If the device has been dropped, exposed to high levels of
moisture or suered any other damage, it must no longer be
used. If in doubt, contact Customer Services or the retailer.
The steam vaporiser may only be operated with the approp-
riate accessories.
CAUTION
Power cuts, sudden interference or other unfavourable condi-
tions could lead to the device becoming inoperable. For this
reason, we recommend that you have aspare device at your
disposal.
Never use the device with extension cables.
Never store the device or the power cable near to sources
of heat.
Do not use the device in aroom in which aspray has previ-
ously been used. Air the room before carrying out the treat-
ment.
Never insert anything into the vents.
Never block the vents.
Never use the device when the aroma container is empty.
Never use the device when the water heater tank is empty.
For hygiene reasons, it is essential that every user uses their
own accessories.
Always disconnect the mains plug from the mains socket after
use.
Store the device in alocation protected against climatic in-
fluences. The device must be stored in the environmental
conditions specified.
PROTECTION
The device has aprotection fuse. This may only be replaced
by authorised specialist personnel.
The device also has athermal fuse, which switches the steam
vaporiser o if it overheats. In the event of overheating, the
background
5
light on the ON/OFF switch turns o automatically. If this hap-
pens, proceed as follows:
1. Switch o the device first.
2. Pull the mains plug out of the socket.
3. Wait for at least 30 minutes until the device has cooled down
completely.
4. Switch the device back on and check whether it is working
properly again. If it does, you can continue using the device
again. If it does not, please contact Customer Services or an
authorised retailer.
General notes
CAUTION
The device is suitable only:
- for use on people,
- for the purpose for which it was developed and as speci-
fied in these instructions for use.
Any form of improper use can be dangerous.
In the event of an acute emergency, providing first aid must
take top priority.
Only use distilled water and aroma oils. Other liquids may po-
tentially cause afault in the steam vaporiser.
This device is not intended for commercial or clinical use; it
is designed exclusively for self-treatment in aprivate home.
Prior to initial use
CAUTION
Remove all packaging material before using the device.
Protect the device against dust, dirt and humidity and never
cover the device while it is in use.
Do not operate the device in avery dusty area.
Switch the device o immediately if it is faulty or not working
properly.
The manufacturer is not liable for damage resulting from im-
proper or incorrect use.
Repairs
NOTICE
Under no circumstances should you open or repair the device
yourself, as faultless functionality can no longer be guaran-
teed thereafter. Failure to comply with this instruction will void
the warranty.
The device is maintenance-free.
For repairs, please contact Customer Services or an autho-
rised retailer.
5. DEVICE DESCRIPTION
The associated drawings are shown on page 3.
1
Aroma mask
2
Variable steam regulator
3
Cover
4
Lid
5
Water heater tank
6
ON/OFF switch
7
Mains connector cable
8
Return container
9
Aroma container
10
Suction tube
11
Nozzle
12
Facial sauna mask
6. INITIAL USE
NOTICE
Follow the instructions in the Chapter “Cleaning and disinfection”
before using the device for the first time or if it has not been used
for an extended period.
1.
Remove the device from the packaging. Ensure that there is
amains socket close to the set-up area.
2.
Place the device on a firm, even surface and pull the cover
up and o by pressing the button above the aroma container/
return container.
A
3.
Remove the sticker with the warning notice from the cover.
Twist the lid anti-clockwise. Observe the marking on the lid
when you do this. Remove the lid.
B
4. Fill the water heater tank with approx. 25 ml of water (do not
fill the water heater tank above the “MAX” marking). Always
use water to fill the water heater tank and never use any other
liquids.
C
5.
Refit the lid and close it tightly by turning it clockwise. Observe
the marking on the lid when you do this.
6. Replace the cover from above.
7.
Pull out the aroma container/return container. Fill the aroma
container with the liquid that you want to atomise (e.g. salt-
water solution). Never fill the aroma container above the “MAX”
marking (60ml).
D
8.
Re-insert the aroma container/return container into the device.
Make sure that the suction tube touches the bottom of the aro-
ma container.
E
background
6
9. Push the variable steam regulator down to produce smaller
steam particles, and push it up for larger ones.
F
10. Make sure that the ON/OFF switch is in the “OFF” positi-
on. Arrange the mains cable in such away that no-one will
trip over it. Insert the mains plug into asuitable socket. The
device must only be connected to the mains voltage that is
specified on the type plate.
11. Select the desired mask for your application (aroma or facial
sauna mask).
12. Move the ON/OFF switch to the “ON” position.
7. USAGE
After approx. 2 minutes, the device will start to produce steam.
Since each person’s temperature sensitivity is dierent, we re-
commend starting use with sucient distance. Do not hold your
face directly against the mask. Gradually reduce the distance.
Ensure that steam does not escape from the mask and into the
eyes. As a result, it is recommended that you close your eyes
during treatment.
Treatment with aroma mask during the cold
season
During use, sit in an upright and relaxed position at a table and
not in an armchair, so as to avoid compressing the airways and
therefore impairing eectiveness. Breathe in deeply.
Treatment with facial sauna mask for cosmetic
facial care
Sit in front of the device. Bend forward far enough that your face
is over the mask. After the treatment, wash your face with cold
water. Now apply a facial cream or face mask. The open pores
allow the active ingredients to penetrate deep into the skin. Do
not use the facial sauna for more than a total of 20 minutes per
day. It is recommended that 2 to 3 treatments are performed per
week As soon as the production of steam starts to diminish (ma-
ximum duration approx. 10 minutes), turn the ON/OFF switch to
the “OFF” position.
After each use, pull the mains plug out of the socket. Allow the
device to cool down completely (approximately 10 minutes).
Clean the device and the mask used after every use as described
in the “Cleaning and maintenance” chapter
8. CLEANING AND MAINTENANCE
WARNING
Adhere to the following hygiene instructions to avoid health risks.
The device must be switched o, disconnected from the mains
and allowed to cool down each time before cleaning.
The device must be cleaned after every use
1. Make sure that the device has cooled down (approx. 10 mi-
nutes), the ON/OFF switch is in the “OFF” position and the
device has been disconnected from the power supply.
2. Pull the cover of the device up and o by pressing on the
button above the aroma container/return container.
3. Twist the lid anti-clockwise. Observe the marking on the lid
when you do this. Remove the lid. Empty any remaining water
from the water heater tank. Then dry it with aclean cloth or let
it air-dry completely. Residual moisture or wetness represents
an increased risk of bacterial growth.
B
4. Pull out the aroma container/return container.
D
5. Clean the aroma container/return container, the cover, the lid,
the extension tube and the mask with warm water and a mild
cleaning agent. Clean these parts thoroughly and allow them
to dry completely. Residual moisture or wetness represents
an increased risk of bacterial growth.
6. Once the parts are completely dry, you can reassemble the
device.
7. Store the device in acool, dry place.
Cleaning the main unit
Never submerge the main unit in water.
Clean the main unit using a soft, slightly damp cloth and
a mild cleaning agent. Then wipe dry with a soft, lint-free
cloth. Do not use any chemical or abrasive cleaning agents.
NOTICE
Any other cleaning method or type of cleaning product could da-
mage the device. Failure to comply with this instruction will void
the warranty.
Cleaning the nozzle
NOTICE
Periodically, the nozzle that directs the steam into extension tube
may become blocked. When the device starts to produce sig-
nificantly less steam, or no steam at all, you need to clean the
nozzle.
1. Pull the cover up and o.
2. Turn the nozzle in aclockwise direction. Pull the nozzle up
and o.
3. Insert athin object (for example aneedle) into the nozzle in
order to clean the air duct.
G
4. To reattach the nozzle, align the grips of the nozzle with the
recesses on the nozzle head. Turn the nozzle anticlockwise,
until you feel the grips of the nozzle click into place.
Disinfection
The relevant mask can be disinfected using boiling water.
Remove the mask from extension tube.
Place the mask into boiling water for 5 minutes.
background
7
Then dry the mask carefully using asoft cloth.
Re-attach the mask to the extension tube once it has com-
pletely dried.
Storage
Do not store in damp conditions (such as in abathroom) and
do not transport with any damp items.
When storing and transporting, protect from prolonged direct
sunlight.
Store the device in a dry place, ideally in the original pa-
ckaging.
9. ACCESSORIES AND REPLACEMENT
PARTS
Designation Material REF
Mask PVC 601.34
Facial sauna mask PVC 603.85
10. WHAT IF THERE ARE PROBLEMS?
Problem/ques-
tion
Possible cause/remedy
The ON/OFF
switch has been
switched on, but
the device is not
working.
1. Check the power connection to the so-
cket and check whether the mains plug
has been plugged in correctly.
2. The device has a thermal fuse. Fol-
lowing switch-o, the mains plug must
be pulled out and a waiting period
observed (see the section on fuses in
Chapter 3 „Warnings and safety notes“).
The device is
switched on but
produces no
or hardly any
steam.
1. Check that there is water in the contai-
ner of the water heater tank.
2. Check that there is liquid in the aroma
container.
3. Make sure that the suction tube and
other components have been attached
properly.
4. Check the
nozzle for blockages. Clean
the nozzle if necessary (see “Cleaning
the nozzle” section in the “Cleaning and
disinfection” chapter)
Does everyone
need aseparate
mask?
Yes, this is absolutely essential for hygiene
reasons.
11. DISPOSAL
For environmental reasons, do not dispose of the device in the
household waste.
Please dispose of the device in accordance with EC Di-
rective – WEEE (Waste Electrical and Electronic Equip-
ment).
If you have any questions, please contact the local au-
thorities responsible for waste disposal.
12. TECHNICAL SPECIFICATIONS
Model SI 40
Dimensions (Includes
Facial sauna mask)
(WxHxD) 300 x 315 x 130 mm
Weight 738 g
Filling volume of internal
water heater Max. 25 ml
Aroma container filling
volume Max. 60 ml
Mains connection 220 – 240 V~; 50 – 60 Hz
Steam temperature Approx. 43°C
Water boiling time Approx. 2 minutes
Maximum operation time Approx. 10 minutes
Operating conditions Temperature: +10°Cto +40°C
Relative humidity: 10% to 95%
Ambient pressure:
700 hPa to 1060hPa
Storage and transporta-
tion conditions
Temperature: 0°Cto +60°C
Relative humidity: 10% to 95%
Ambient pressure:
500hPa to 1060hPa
Subject to technical changes.
Please contact the specified service address to obtain further in-
formation, such as the CE Declaration of Conformity.
13. WARRANTY / SERVICE
Further information on the guarantee and guarantee conditions
can be found in the guarantee leaflet supplied.
Subject to errors and changes