Mini Circuit Breaker
QP 125A Frame Circuit Breaker
1 - 2 and 3-pole; 10A -125A
usa.siemens.com/resibreakers
Q120
Q220
Q320
Catalog Numbers
Amperage Poles QP QPH HQP
10 1 Q110 – –
15 1
Q115
a
Q115H
a
Q115HH
a
20 1
Q120
a
Q120H
a
Q120HH
a
25 1 Q125 Q125H Q125HH
30 1 Q130 Q130H Q130HH
40 1 Q140 Q140H Q140HH
45 1 Q145 Q145H Q145HH
50 1 Q150 Q150H Q150HH
60 1 Q160 Q160H Q160HH
70 1 Q170 Q170H Q170HH
Amperage Poles QP QPH HQP
10 2 Q210 – –
15 2 Q215 Q215H Q215HH
20 2 Q220 Q220H Q220HH
25 2 Q225 Q225H Q225HH
30 2 Q230 Q230H Q230HH
40 2 Q240 Q240H Q240HH
45 2 Q245 Q245H Q245HH
50 2 Q250 Q250H Q250HH
60 2 Q260 Q260H Q260HH
70 2 Q270 Q270H Q270HH
80 2 Q280 Q280H Q280HH
90 2 Q290 Q290H Q290HH
100 2 Q2100 Q2100H Q2100HH
110 2 Q2110 Q2110H Q2110HH
125 2 Q2125 Q2125H Q2125HH

Amperage Poles QP QPH HQP
15 2 Q215R – –
20 2 Q220R – –
25 2 Q225R – –
30 2 Q230R – –
40 2 Q240R – –
45 2 Q245R – –
50 2 Q250R – –
Amperage Poles QP QPH HQP
15 3 Q315 Q315H Q315HH
20 3 Q320 Q320H Q320HH
25 3 Q325 Q325H Q325HH
30 3 Q330 Q330H Q330HH
40 3 Q340 Q340H Q340HH
45 3 Q345 Q345H Q345HH
50 3 Q350 Q350H Q350HH
60 3 Q360 Q360H Q360HH
70 3 Q370 Q370H Q370HH
80 3 Q380 Q380H Q380HH
90 3 Q390 Q390H Q390HH
100 3 Q3100 Q3100H Q3100HH
UL 489 Interrupting Ratings
Breaker
Type
UL A.I.R. (kA) RMS Symmetrical
Amperes Volts AC (50/60 Hz)
120 120/240 240
QP
10 10 -
- - 10
- 10 -
- - 10
QPH
22 22 -
- 22 -
- - 22
HQP
65 65 -
- 65 -
- - 65
Standards:
UL 489
CSA C22.2 NO. 5-16
NMX-J-266-ANCE
Special Application Breakers
Type Amperage Poles Catalog Number
HID
15 1 Q115HID
20 1 Q120HID
30 1 Q130HID
15 2 Q215HID
20 2 Q220HID
30 2 Q230HID
Molded Case Switch
100 1 Q1100S
30 2 Q230S
50 2 Q250S
60 2 Q260S
125 2 Q2125S
No-Noise
50 2 Q250NN
60 2 Q260NN
Switching Neutrals
15 2 QG215
20 2 QG220
20 3 QG320
a UL Listed for frequent switching applications (SWD).
All QP, QPH and HQP are UL listed for use with 60/75° wire through 40 amps, UL listed for use
with 75° wire only for 50 amps and above, HACR rated.

3"
2
3
/
8
"
3
1
/
8
"
1-Pole 2-Pole 3-Pole
QP, QPH, HQP
Pressure Wire Connectors
Load Side terminal factory installed only
Breaker Type
Ampere
Rating
Cables
per Lug
No. of
Poles Wire Range
QP, QPH & HQP
15 - 20
1 1, 2, 3 #14 - #10 AWG Cu
1 1, 2, 3 #12 - #10 AWG Al.
25 - 35
1 1, 2, 3 #10 - #8 AWG Cu.
1 1, 2, 3 #10 - #6 AWG Al.
40 - 50
1 1, 2, 3 #8 - #6 AWG Cu.
1 1, 2, 3 #8 - #4 AWG Al.
QP
55 - 60
1 1, 2 #6 - #4 AWG Cu.
1 1, 2 #6 - #4 AWG Al.
55 - 60
1 3 #6 - #3 AWG Cu.
1 3 #6 - #3 AWG Al.
QPH & HQP 55 - 60
1 1, 2, 3 #6 - #3 AWG Cu.
1 1, 2, 3 #6 - #3 AWG Al.
QP, QPH & HQP
70 - 100
1 1, 2, 3 #4 - #3 AWG Cu.
1 1, 2, 3 #3 - #1 AWG Al.
110 - 125
1 2 #2 - #1/0 AWG Cu.
1 2 #1/0 - #2/0 AWG Al.
Shunt Trip
Description Catalog Number Field/Factory Installed
120VAC add suffix…00S01 Factory
24VAC add suffix…00S07 Factory
Auxiliary Switch
Description Catalog Number Field/Factory Installed
120VAC add suffix…01 Factory
Description Catalog Number
non-UL 50C calibration add suffix…M
400 Hz Calibration
a
add suffix…Y
Fungus Proofing add suffix…F
a
UL listed 5kA max A.I.R.
External Accessories
Description Catalog Number No. of Poles
Padlocking Device
ECPLD1 1
ECPLD1R 1
ECPLD2 2
ECPLD2R 2
ECPLD3 3
ECPLD3R 3
ECQLD4 1
ECQTH4
Designed for (3)
1P Breakers
Handle Tie
ECQTH2 1
ECQTH3 2
Handle Blocking Device
ECQTH2 1
ECQTH3 1

Published by
Siemens 2020
Siemens Industry, Inc.
3617 Parkway Ln.
Peachtree Corners, GA 30092
Siemens Technical Support: 1-800-333-7421
Printed in USA-CP
Order No. RPDS-QP125-1020
All Rights Reserved
© 2020, Siemens Industry, Inc.
usa.siemens.com/resibreakers
The technical data presented in this document is based on an actual case or on
as-designed parameters, and therefore should not be relied upon for any specific
application and does not constitute a performance guarantee for any projects.
Actual results are dependent on variable conditions. Accordingly, Siemens does
not make representations, warranties, or assurances as to the accuracy, currency
or completeness of the content contained herein. If requested, we will provide
specific technical data or specifications with respect to any customer’s particular
applications. Our company is constantly involved in engineering and development.
For that reason, we reserve the right to modify, at any time, the technology and
product specifications contained herein.