Guangdong Grasse Environmental Technology GAS-101 Scent Machine

Product's Documents

Below are documents related to this product, you can read online or download:

User Manual

This is the main product document for model GAS-101.

The file format is pdf, 3 pages, you can download this manual here .

background
background
@ Mode Setting: 5-segment wo「king mode. Tap any column to
customize the weekly schedule
,
set power-on and power-off times,
and ad」ust the 1ntens1ty level, etc
Oa,s
Set weekly working
hours and select the
--
---
··
..
days of the week for
device operation
OB oo
22 oo
--------
Set the start and end
times for the device's
operation
Sea
Select 1ntens1ty levels
Low(LOW)
,
-•.
Medium (ME
D)
,
and High (HIGH
)
®Additional settings: Click the top right corner to set the device
name, avatar, and password
aoo,oo," 00,.,s.m� X
"""'·"-"
_,
沁"'沁对
111W//I倡
09/Concentration & Consumption
Mode
Worktime/s
Stop time/s
Consumpt1on(h)
Minimum
15s
300s
0 05
Medium
15s 180s
0 08
Maximum
15s
60s 0 22
100% Power
Fully Open
1 08
1 The above data is based on the fragrance oil tested
Park Hyatt (density王095
)
2 The above data is for reference only, and the amount of
atomization rate may vary when using different fragrance oils
10/Atomizer Replacement
The atomizer assembly includes the atomizing head, oil bottle,
and the relevant atomizing units.
Steps. (1)Unscrew the oil bottle. (2)Wipe off any remaining oil with
a dry cloth. (3)Remove the atom1z1ng unit that need replacement
(4)Securely install the new atom1z1ng unit ,n place
i
I
.
二-
I
'
'
I
I
I
I
I
11/Equipment Maintenance
If the device will not be used for an extended pe「iod, clean the
nozzle and internal parts by filling the empty oil bottle with 95%
industrial alcohol.
Operation:(l)Fill the empty bottle with 95% industrial alcohol.
(2)Attach it to the device and turn it on. (3)Let it run for 10-15
minutes, then turn it o (4)Pour out the alcohol and screw the bottle
back onto the machine
12/Warranty
The warranty applies only to new machines, not resold or
second-hand units.
We provide a 12-month warranty from the date of purchase for all
eligible machines. During the warranty period, we offer repair
services and free replacement parts (excluding fragrance oils)
Awa「ranty card and com me「cial invoice are 「equired for any
service request. Please contact us w1th1n the warranty period 1f any
issues occur.
The following cond1t1ons are not covered
Damage caused by accidents, fire, or natural disasters
®Improper use or incorrect operation.
®Damage resulting from unauthorized repairs or mod1f1cat1ons
©Damage incurred during transportation
®Missing warranty card
®Lack of regular maintenance or cleaning
0Damage caused by overloading or operating the machine
beyond its recommended working time.
®Machines or parts not supplied by us
®Machines not purchased through authorized channels
画Returning the machine without prior approval from the
manufacturer.
13/Precautions
Read the manual carefully and keep ,t for future reference
Empty the bottle during transport to prevent leaks and damage
Keep the device upright while filling; do not tilt or invert
Do not cove「 the device while it is in operation to avoid blocking
airflow or mist. Make sure the power socket or adapter is not placed
above the mist outlet to prevent prolonged exposure to the spray
,
which could damage the adapter and cause power problems
Avoid overloading or damaging power cords and plugs, and
ensure the lithium battery is not damaged
Do not disassemble the device. Contact us 1f any issues arise
Scent Machine
USER MANUAL
GAS-101
CE氏@
Ba
e
r
y ty
p
e
Note: The remote c
ontrol has an infrared function
background
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause
undesired operation.
Any Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
-This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.

Specifications

Indexed Terms: Scent Machine

Guangdong Grasse Environmental Technology GAS-101 Questions and Answers

Questions and Answers

Related Products