Medisana HM 860 Wireless Handheld Massager

Product's Documents

Below are documents related to this product, you can read online or download:
HM 860 photo

User Manual HM 860

This is the main product document for model HM 860.

The file format is pdf, 1 pages, you can download this manual here .

background
Make sure that no ngers or other body parts get between the receptacle
for massage heads and the massage heads. Risk of injury!
Do not use the appliance when sprayed from aerosol cans or when oxygen is
used at the same time.
For maintenance and cleaning
The unit is maintenance-free. You may only carry out cleaning work on the unit
yourself. In the event of malfunctions or damage, do not repair the unit yourself,
as this will invalidate any warranty claims. Ask your specialist dealer and have
repairs carried out only by authorised service centres in order to avoid hazards.
Do not immerse the unit in water or other liquids. Should liquid ever get into the
unit, unplug it from the mains immediately.
Cleaning and user maintenance must not be carried out by children without
supervision.
Intended use
The device is used for self-massage of the muscles for relaxation and
regeneration. Do not use the device on the head or other hard or bony parts
of the body! Do not use the device on sensitive parts of the body!
The device is not intended for medical-therapeutic use. It is not suitable for clinics,
massage practices, wellness studios, etc. The massager is not a medical device
and is not intended for the treatment of pain. In case of doubt or uncertainty, ask
your doctor before use.
Unit and controls
1
Massage modes (15 modes)
2
Accelerate intensity (15 levels)
3
Decelerate intensity (15 levels)
4
ON/OFF button
Scope of delivery
Please check rst whether the unit is complete and does not show any damage. If
in doubt, do not operate the unit and contact your dealer or service centre.
The scope of delivery includes:
• 1 medisana Wireless Handheld Massager HM 860
• 7 massage heads, 1 crystal gel massage head
• 1 USB to Micro-USB charging cable
• 1 wall charger
• 1 instruction manual
Massage heads
The following are examples of how to use the massage heads.
However, everyone feels the massage of certain points and muscles differently. Try
out all the massage heads and nd the one that suits you best.
GB INSTRUCTION MANUAL Wireless Handheld Massager HM 860
Explanation of symbols
IMPORTANT
Non-observance of these instructions
can result in serious injury or damage
to the device.
WARNING
These warning notes must be observed
to prevent any injury to the user.
CAUTION
These notes must be observed to
prevent any damage to the device.
NOTE
These notes give you useful additional
information on the installation or
operation.
The massage device must only be used
in enclosed spaces!
Do not use the massage device in
damp rooms (e.g. when bathing or
showering).
Protection category III
LOT number
Manufacturer
Device and controls
Read the instruction manual carefully before using this device,
especially the safety instructions, and keep the instruction manual
for future use. Should you give this device to another person, it is
vital that you also pass on these instructions for use.
GB Safety instructions
WARNING
Please ensure that polythene packing is kept away from the reach
of children! Risk of suffocation!
In accordance with our policy of continual product improvement,
we reserve the right to make technical and visual changes without notice.
Warranty and repair terms
Please contact your dealer or the service centre in case of a claim under the warranty.
If you have to return the unit, please enclose a copy of your receipt and state what the
defect is. The following warranty terms apply:
1. The warranty period for medisana products is three years from date of purchase.
In case of a warranty claim, the date of purchase has to beproven by means of the
sales receipt or invoice.
2. Defects in material or workmanship will be removed free of charge within the
warranty period.
3. Repairs under warranty do not extend the warranty period either for the unit or for
the replacement parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. non-observance of
the user instructions.
b. All damage which is due to repairs or tampering by the customer or unauthorised
third parties.
c. Damage which has arisen during transport from the manufacturer to the
consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear.
5. Liability for direct or indirect consequential losses caused by the unit are excluded
even if the damage to the unit is accepted as a warranty claim.
6 7 8 0
q
9
48236_HM 860_manual_GB_202309_L2
Only use the appliance for the purpose for which it is intended in accordance
with the instructions for use. Any misuse will invalidate the warranty.
The unit is not intended for commercial purposes or the medical sector.
For power supply
Before connecting the unit to the power supply, make sure that it is switched
off and that the electrical voltage indicated on the label matches your mains
voltage.
Keep the charging adapter, cable and device away from heat, hot surfaces,
moisture and liquids.
Do not touch the charging adapter when standing in water or when your hands
are wet or damp.
The unit must be connected so that the mains plug is freely accessible.
To disconnect the unit from the mains, never pull on the mains cable but
always on the mains plug.
Do not carry, pull or turn the appliance by the mains cable.
If the mains cable is damaged, it must only be replaced by the manufacturer,
an authorised dealer or a suitably qualied person.
The unit’s cable can become a hazard (strangulation, tripping) if it is not routed
correctly. The user must ensure that the power cable is laid safely.
For special persons
This unit may only be used by persons over 18 years of age.
Children must not play with the appliance.
Do not use this device to support or replace medical applications. Chronic
ailments and symptoms could be aggravated.
You should refrain from using the massager or consult your doctor rst if:
- you are pregnant,
- you have a pacemaker, articial joints or have electronic implants.
- you suffer from one or more of the following diseases or medical conditions:
Diabetes, circulatory disorders, varicose veins, open wounds, bruises, skin
tears, phlebitis.
If you experience pain or nd the massage uncomfortable, discontinue use and
speak to your doctor.
In case of unexplained pain, if you are undergoing medical treatment and/or
using medical equipment, consult your doctor before using the massager.
Before using the appliance
Check the massager carefully for damage before each use. Do not use a
defective appliance.
Do not use the appliance if any damage is visible, if it is not working properly, if
it has been dropped or if it has become wet. To avoid hazards, send the unit to
the service centre for repair.
When operating the unit
Do not use the unit when you are sleeping or in bed.
Do not use the appliance before falling asleep. The massage has a stimulating
effect.
Never use the appliance when driving a vehicle or operating machinery.
Do not store or keep any electrical appliance in places from where it can fall
into the bathtub or sink.
The maximum operating time for one application is 15 minutes. Prolonged use
will shorten the life of the appliance and may cause muscle tension instead of
relaxation.
Excessive use can lead to overheating. Always allow the unit to cool down
before using it again.
Never place or use the device directly next to an electric heater or other
sources of heat.
This appliance should not massage the skin surface directly to avoid damage
to the skin. The massage part should be covered with clean, dry clothing or a
clean, dry towel. It should be pressed and moved gently. The massage time on
the same spot should not exceed 60 seconds.
Do not leave the appliance unattended when it is connected to the mains or
switched on.
Avoid contact of the unit with pointed or sharp objects.
Do not cover the unit when it is switched on.
Never use the unit under blankets or pillows. There is a risk of re, electric shock
and injury.
6
Shiatsu Massage Head
Replicates the sensation of nger pressure massage and can be used on
most areas of the body.
7
Round Nodule Massage Head
Suitable for most parts of the body, creating a pressing sensation during
massage.
8
6-Edge Hammer Massage Head
Designed for pinpoint massage of large muscle groups, such as the limbs,
waist, back, and hips.
9
Acupuncture Massage Head
Suitable for stimulating specic areas and tapping densely populated areas,
such as the palms, soles of the feet, and acupuncture points.
0
Round Massage Head
Can be used on most areas of the body and simulates a st pounding
massage.
q
Crystal Gel Massage Head
Suitable for use on most areas of the body. This massage head can be used
for cold massage therapy
w
5-Node Protruding Massage Head
With a larger massage area, this massage head is ideal for massaging the
back, waist, and legs, and can be used for full-body massage.
e
U-Shaped Multi-point Massage Head
Simulating multi-point massage. This massage head is suitable for use on
the shoulders, neck, and legs.
Unit E&F, 31/F, YHC Tower, 1 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Using the unit
Charging the battery
Connect the supplied USB cable to the charging socket
5
of the unit and the wall
charger. Number “88” will be ashing on the display. When the battery is fully
charged (after 3 to 5 hours), Number “88” will stop ashing. The unit cannot be
used during the charging process.
Operation
1. Hold the ON/OFF button
4 to switch on the device.
2. Press the Massage Modes button
1 to switch between 15 massage modes.
3. Press the intensity button
2/3 to accelerate/decelerate the vibration level.
Switching off the unit
Hold ON/OFF button
4
to switch off the device. The unit switches off automatically
after 15 minutes.
Cleaning and maintenance
Before cleaning the appliance, make sure that the appliance is switched off. Let
the appliance cool down.
Clean the massager only with a slightly damp sponge. Never use brushes,
strong detergents, petrol, thinner or alcohol. Rub the massager dry with a clean,
soft cloth. Do not dry on the heater or with a hair dryer.
Never immerse the appliance in water to clean it and make sure that no water or
other liquid enters the appliance.
Do not use the appliance again until it is completely dry.
It is best to store the appliance in a safe, clean, cool and dry place.
Disposal
This product must not be disposed of together with domestic waste
All users are obliged to hand in all electrical or electronic devices,
regardless of whether or not they contain toxic substances, at a
municipal or commercial collection point so that they can be disposed
of in an environmentally acceptable manner. Consult your municipal
authority or your dealer for information about disposal.
Technical data
Name and model: medisana Wireless Handheld Massager HM 860
Input voltage: DC 5V
1A
Battery: 7.4V, 2000 mAh
Power consumption: 16W
Wall charger: Input: 100~240V, 50/60Hz
Output: 5V
Charging time: 120 - 180 minutes
Dimensions: Approx. 47 x 16.5 x 11 cm
Weight: Approx. 765 g
Storage conditions: clean and dry
Item number: 48236
EAN number: 40155 88 48236 6
w
e
4
3
1
2
5

Specifications

Indexed Terms: Handheld Massager, Wireless