20
INSTALLATION
• Amper cord is used it must be marked
for use with a 1 3/8 inches (35 mm)
diameter opening. Cord must have either
3 or 4 conductors to match electric
receptacle (Use copper or Aluminum
Conductors).
!
Warning: Risk of fire or electrical shock
exists if an incorrect size appliance cord
kit is used or the Installation manual or
strain relief clamp are disregarded.
!
Warning: Do not loosen the nuts which
secure the factory-installed range wiring
to the terminal block while connecting
range. Electrical failure or loss of
electrical connection may occur.
• When installed where it is not permitted
to ground through the neutral, a
4-conductor cord must be used or
cable assembly. See manufacturer's
instructions.
• The main supply data must correspond
to the data specified on the rating label
of the appliance. The rating plate is either
seen when the door is opened.
3 & 4 -wire electrical wall receptacle
types & recommended mounting
orientation on wall
• Figure A illustrates 4-wire receptacle
required for new branch circuit
installation (1996 NEC) mobile homes,
and recreational vehicles or where local
codes do not allow grounding thru the
neutral.
• Figure B illustrates 3-wire receptacle that
is allowed in areas that allow grounding
through neutral.
• A) 4-wire wall receptacle.
• B) 3-wire wall receptacle (10-50R)
Access to terminal block
!
Warning: Read carefully and follow the
instructions below.
•
Loosen the one screw on terminal cover
and take off as showing in picture.