26
English
Cleaning at a Glance
Cleaning and Maintenance
Periodical maintenance
Unit Maintenance item Interval
Requires qualified
technicians
Indoor unit
Clean the air filter. Once every 2 weeks
Clean the condensate drain pan. Once a year Required
Clean up the heat exchange. Once a year Required
Clean the condensate drain pipe. Once every 4 months Required
Replace the remote control Batteries. Once a year
Outdoor unit
Clean the heat exchanger on the outside of the unit.
Once every 4 months Required
Clean the heat exchanger on the inside of the unit.
Once a year Required
Clean the electric components with jets of air. Once a year Required
Verify that all the electric components are firmly
tightened.
Once a year Required
Clean the fan. Once a year Required
Verify that the fan assemblies are firmly
tightened.
Once a year Required
Clean the condensate drain pan. Once a year Required
CAUTION
Be sure to perform the maintenance check periodically. This work improves the air conditioner's
efficiency.
The frequency of maintenance work may vary depending on the geographical area, amount of dust,
and other environmental elements. If the air conditioner is installed in a very dusty place, perform the
maintenance work more frequently.
Make sure that the maintenance work must be done by qualified technicians. For more detailed
information, refer to the Installation manual.