Rinnai 9 HW_CF OIM
Temperature Control
Water controllers allow precise temperature control by the user� When used correctly, the hot water unit will deliver
the selected temperature, even when the water ow is varied, or more than one tap is in use.
Only one MC model water controller can be designated as a ‘Master water controller and this is normally used
in the kitchen� All the remaining water controllers are designated as ‘Sub’ water controllers and are for use in
bathrooms, toilets and laundries� The maximum temperature limit for all ‘Sub’ water controllers is restricted to 50°C
to minimise the risk of burns in these areas�
Each water controller can be individually programmed, however the water heater can only deliver one set
temperature at any time. The available temperatures (°C) are as follows:
Water Controller
Temperatures (°C)**
Master (MC) 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55*, 60*, 65*
Sub (MC or BC) 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50
For hygiene in sanitary areas such as bathrooms, the suggested temperature should be 37°C ~ 43°C�
The above is a suggestion only, as you may nd higher or lower temperatures more comfortable, however
maintaining lower temperatures also helps to save energy
To obtain water temperatures lower than 37°C, simply open the cold water tap and add cold water until the desired
lower temperature is reached�
NOTE
The temperature of outgoing hot water is constantly monitored by a built-in sensor� If the
temperature of the outgoing hot water rises to more than 3°C above the selected temperature
shown on the digital monitor or the pre-set limit when water controllers are not tted, the burner
will automatically go out� The ‘in use’ indicator will also go out� The burner will ignite again
once the outgoing hot water temperature falls to that shown on the digital monitor (or the pre-set
limit of the appliance)
* Temperature may not be available on all installations� Some Rinnai Continuous Flow water
heaters can be programmed to deliver higher temperatures from the master water controller, or
may be programmed to restrict the maximum available delivery temperature� Contact Rinnai for
more details�
** Temperature limiting devices (where tted) may further control what maximum delivery
temperature is available to outlets�
Universal and Wireless and water controllers allow temperature selection only� Deluxe water controllers allow
temperature selection, have a clock function and the Deluxe Bathroom water controller has a shower saver / bath
ll function is also available, contact Rinnai for further information regarding Wireless and Deluxe water controllers
or visit www�rinnai�com�au�
WATER CONTROLLER COMBINATIONS & CONFIGURATIONS
Wired Only Congurations
A maximum of 4 water controllers can be tted. Any combination of deluxe and universal controllers can be
used with the following limitations:
Only ONE master controller can be installed� This can be a MC-100V, or a MC-601Q (when programmed as
a master controller). Note that when a MC-100V is tted it will always functions as a master controller, this
is the default setting and can not be changed�
Up to TWO BC-100V water controllers can be installed�
The FOURTH water controller in any installation MUST BE a MC-601Q�
Combined Wireless & Wired Congurations
A maximum of 4 water controllers can be tted. Any combination of deluxe, universal and wireless controllers
can be used with the following limitations:
Only ONE master controller can be installed� This can be a MC-100V, a MC-601Q (when programmed as
a master controller) or a MC-503RC-S water controller. Note that when a MC-100V is tted it will always
functions as a master controller, this is the default setting and can not be changed�
Up to TWO BC-100V water controllers can be installed�
The FOURTH water controller in any installation MUST BE a MC-503RC-S or a MC-601Q�
WATER TEMPERATURE CONTROL