Rinnai 17 HW_CF OIM
HOT WATER DELIVERY TEMPERATURE
Local regulations and or the requirements of AS/NZS 3500 MUST BE addressed regarding the temperature
limitations of hot water supplied to areas used primarily for personal hygiene� The temperature of water to these
areas may be limited to 50°C or less�
To ensure these regulations and or requirements are met the system MUST BE installed in accordance with the
"Water Controller Combinations & Congurations" on page 9 and "Water Controllers Limitations" on page 20
of these instructions�
Installation Congurations
If the appliance is marked to state that it delivers water not exceeding 50°C, local regulations may permit installation
without a Temperature Limiting Device� Installations without a Temperature Limiting Device are shown in Diagram
1 below� If you are unsure about your local regulations contact your regulating authority or Rinnai�
If the appliance is NOT marked to state that it delivers water not exceeding 50°C, or your local regulations require
installation with a Temperature Limiting Device then install the appliance in accordance with Diagram 2 below
IMPORTANT
If the appliance is to deliver water primarily for the purposes of personal hygiene in an early
childhood centre, primary or secondary school, nursing home or a similar facility for the care of
young, aged, sick or disabled persons as dened in AS/NZ 3500 a Temperature Limiting Device
(TLD), such as a Tempering Valve may be required even if the appliance is set to 50º C or less�
For these types of applications contact Rinnai�
50º C
KITCHEN
Water controller
(optional)
Water controller
(optional)
Water controller
(optional)
Water controller
(optional)
LAUNDRY
BATHROOM
ENSUITE
H
OT
C
O
LD
G
AS
Diagram 1 : 50°C Appliance
KITCHEN
Water controller
(optional)
Water controller
(optional)
LAUNDRY BATHROOM
Water controller
(optional)
Water controller
(optional)
ENSUITE
TLD
H
OT
C
O
LD
G
AS
Diagram 2 : NOT a 50°C Appliance
NOTE
Minimum length of pipe from hot outlet
to nearest hot water tap 2 metres�
NOTE
TLD = Temperature Limiting Device�
Universal water controllers are available as an optional extra and will function as described in the Operation Section
of this manual. Refer to "Water Controller Combinations & Congurations" on page 9 and "Water Controllers
Limitations" on page 20 to conrm the maximum number and combination of water controllers that can be tted.
For detailed installation information of Universal water controllers refer to the "Water Controller Installation" chapter
of this manual starting on page 20�
Operation and Installation information for Deluxe and Wireless water controllers is provided with the water
controllers or visit www�rinnai�com�au�