246
(3) Threshold level
(4) Configuration information
(5) Decode the data packet, detailed as follows
(6) Decode data and the corresponding waveform area
UART decode data packet description:
(1) Decode data packet displays real-time data about the bus activities;
(2) Decode data displays as hexadecimal system in white;
(3) When the word length is 5-8 bits, the decode data displays as two bits of hexadecimal; when the word
length is 9 bits, the decode data displays as 3 bits of hexadecimal, and the 9th bit displays at the left side;
(4) When there is error in decode data, if the error is at stop bit, the data displays in yellow, if it is parity error,
data displays in red;
(5) When “?” appears, the time base needs to be adjusted to view decode results.