Electric Power Supply Requirements
14
Pressure Regulator
Recommended
power outlet area
20" 4/5 (530)
26" 4/5 (680)
38" 1/2 (980)
For reference only, please refer to the real object.
Since service pressure may fluctuate with local demand, every gas cooking range must be equipped
with a pressure regulator on the incoming service line for safe and efficient operation.
For GAS RANGE models : The pressure regulator shipped with the range has two female threads
1/2" NPT for the 30" and the 36" or 3/4" NPT for the 48".
For DUAL FUEL models : The pressure regulator shipped with the range has two female threads
1/2" NPT for the 30" and the 36" or 3/4" NPT for the 48".
The regulator is preinstalled in order to be accessible when the appliance is installed in its final
position.
Gas Shut-off Valve
Pressure regulator can withstand
a maximum input pressure of 0.5
psi (3.5 kPa), and is set at 5"
WC outlet pressure when used
on NATURAL GAS and 10" WC
outlet pressure when used on
LIQUID PROPANE.
Gas Shut-off Valve
The supply line must be equipped with an approved external gas shut-off valve located near the range
in an accessible location. Do not block access to the shut-off valve. Refer to the illustration below.
A 3/4" (19
mm) ID gas supply line must be provided to the range. If local codes permit, a certified,
3' (.9 m) long, 1/2" (13
mm) or 3/4" (19 mm) ID flexible metal appliance connector is recommended to
connect the unit’s 1/2" NPT
(30" 36") or 3/4" NPT (48") female inlet to the gas supply line. Pipe joint
compounds suitable for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of the system at test pressures in excess of 0.5 psi (3.5 kPa). The appliance
must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the system at test pressures equal to or less than 0.5 psi (3.5 kPa).
(not included)
P
X
GAS INLET
Pressure Regulator