Area Thermography
Congure the temperature measurement rule and monitor the maximum temperature of the area.
Steps
1.
Click and drag the mouse in the live view to draw the area and right click to nish drawing.
2.
Click and move the area to adjust the
posion.
3.
Drag the corners of the area to adjust the size and shape.
Go to Live View interface to view the maximum temperature and rule of the area in thermal
channel.
Set Temperature Measurement Shield Region
You can congure areas from being detected.
Steps
1.
Go to Conguraon → Local , and enable Display Shield Area.
2.
Check Enable Shield Area.
3.
Click .
4.
Drag the mouse in the live view to draw the area. You can drag the corners of the red rectangle
area to change its shape and size.
5.
Right click the mouse to stop drawing.
6.
Oponal: Select one area and click to delete it.
7.
Click Save.
7.1.4 Manual Thermography
Aer enable the manual thermography funcon of the device, you can click any posion on the
live view to show the real temperature.
Steps
1.
Go to
Conguraon → Local and select Display Temperature Info. as Yes.
2.
Go to Conguraon → Temperature Measurement → Basic Sengs .
3.
Check Enable Temperature Measurement.
4.
Click Save.
5.
Go to live view interface and select thermal channel, click
. Click any posion on the interface
to show the real temperature.
7.2 Fire and Smoke
Detecon
The device will trigger and upload alarm when detect the re source or smoke.