Hikvision DS-TMG300-D/A 30 Series Straight Pole Barrier Gate With LED Light Bar

User Manual - Page 47

For DS-TMG300-D/A.

PDF File Manual, 56 pages, Read Online | Download pdf file

DS-TMG300-D/A photo
Loading ...
Loading ...
Loading ...
Barrier Gate User Manual
41
When the LED displays F-14, press "Confirm" to adjust the rebound response to resistance, and
then press "Open" or "Close" to adjust the reaction time of the rebound when the resistance is
encountered. The larger the value, the longer the reaction time of the rebound. The smaller the
value, the shorter the rebound reaction time when encountering resistance. After adjustment,
press "Confirm" to save the data. (Adjusting this parameter may cause misjudgment by the
controller, it is not recommended to change the value of this parameter unless necessary)
F-15. Set angle to close loop sensor:
When the LED displays F-15, press "Confirm" to adjust the rebound reaction when encountering
resistance, and then press "Open" or "Close" to adjust the angle value of loop sense shielding.
Larger value, the larger the loop sense shielding angle. Smaller value, the smaller the loop sense
shielding angle. Press "Confirm" to save the data after adjustment.
F-16. Set auto-close time without loop sensor:
When the LED displays F-16, press "Confirm" to adjust the delayed closing without loop sensor. 00
means that the delay closing function is turned off, and 01-99 represent the delay closing time
when there is no loop sense. You can set it according to your needs. After adjustment, press
"Confirm" to save the data.
F-40. Delayed closing adjustment with loop sensor:
When the LED displays F-40, press "Confirm" to adjust the delayed closing with loop sensor, 00
means that the delayed closing function is turned off, and 01-99 represent the delayed closing
function with loop sense. You can set it according to your needs, and the unit is second. After
adjustment, press "Confirm" to save the data.
F-21. Set open speed:
When the LED displays "F-21", press "Confirm" to enter the opening speed adjustment, and then
press "Open" or "Close" to adjust the opening speed. The larger the value, the faster the opening
speed. The smaller the value, the slower the speed, press "Confirm" to save the data after
adjustment.
F-23. Set first angle to slow down during open:
When the LED displays "F-23", press "Confirm" to enter the adjustment of the first deceleration
angle of the boom opening, and then press "Open" or "Close". The larger the value, the larger the
deceleration angle of the boom opening. The smaller the value, the smaller the opening
deceleration angle. After adjustment, press "Confirm" to save the data.
F-25. Set deceleration speed during open:
When the LED displays "F-25", press the "Confirm" button to start setting, and then press "Open"
or "Close" button to adjust the opening deceleration speed. The larger the value, the faster the
opening deceleration speed, the smaller the value, the slower the opening deceleration speed.
After setting, press the "Confirm" button to save the data.