5
Wake-Up Notification
The sensor will wake up every so often to send a Wake-Up Notification to allow the life line master node
controller that the sensor is now available for any queued messages that the controller may have for
the sensor. The time between Wake-Up Notifications can be configured with the Wake-Up Notification
command class according to the following configurable values:
• Min Value 1 hr
• Max Value 24 hr
• Default Value 12 hours (12 * 60 * 60 seconds)
• Wake Up Interval Step Seconds 1 hour (3600 seconds)
Z-Wave Command Classes
Command Class Version Required Security Class
Association 2 Highest granted
Association Group Information 3 Highest granted
Device Reset Locally 1 Highest granted
Firmware Update Meta Data 5 Highest granted
Indicator 3 Highest granted
Manufacturer Specific 2 Highest granted
Multi-Channel Association 3 Highest granted
Powerlevel 1 Highest granted
Security 2 1 None
Supervision 1 None
Transport Service 2 None
Version 3 Highest granted
Z-Wave Plus Info 2 None
Notification 8 Highest granted
Wake Up 2 Highest granted
Configuration 4 Highest granted
Battery 2 Highest granted