When using VoltAlert, if the test indicator
does not glow or the beeper does not sound,
hazardous voltage could still be present.
VoltAlert indicates active voltage in the
presence of electric fields of sufficient
strength generated by the source (MAINS)
voltage. If the field strength is low, the
Product may not provide indication of
hazardous voltages. Lack of an indication
may occur if the Product is unable to sense
the presence of voltage which may be
influenced by several factors including, but
not limited to:
- Shielded wire/cables
- Adjacent grounded conductors
- Thickness and type of insulation
- Distance from the voltage source
- Fully-isolated users that prevent an
effective ground
- Receptacles in recessed sockets and/or
differences in socket design
- Condition of the Product and batteries
Use the Product only as specified, or the
protection supplied by the Product can be
compromised.
Do not use the Product around explosive gas,
vapor, or in damp or wet environments.
Do not use the Product if it operates
incorrectly.
Disable the Product if it is damaged.
Keep fingers behind the finger guards on the
Product.
Do not connect directly to mains.
Close and lock the battery door before you
operate the Product.
Do not allow the rod extender to contact live
voltage source.
Do not touch the rod extender while
performing the LAMP TEST. While the LAMP
TEST source voltage is not considered
hazardous for electric shock or electric burn,
the source can cause mild pain or surprise.
For use by competent personnel only.