AXIST8341PIRMotionSensor
HowtoprogramtheZ-Wavedevice
•COMMAND_CLASS_NOTIFICATION_V4
•COMMAND_CLASS_CONFIGURATION
Wake-upcommandclass
AfterthedetectorhasbeenincludedinaZ-Wavenetworkitwillgotosleep,butwillperiodicallysendawake-upnotication
commandtothecontrolleratapresetperiod.Thedevicewillstayawakeforatleast10secondsandthengobacktosleep,to
conservebatterylife.
Thetimeintervalbetweenwake-upnoticationcommandscanbesetinthewake-upcommandclass,basedontherangevalues
below:
Minimumwake-upinterval
600s(10minutes)
Maximumwake-upinterval
86400s(1day)
Defaultwake-upinterval
14400s(4hours)
Wake-upintervalstepseconds
600s(10minutes)