7.2.1 Recommended Scene
This part introduces the recommended scenes of re source detecon and helps you select the
appropriate scene.
Fire source
detecon can be applied to indoor and outdoor monitoring with a large detecon
radius. To achieve the best monitoring eect, please set the installaon place as requirements
below.
The installaon place should be the highest posion within the detecon area. The lens should
not be covered during movement to detect the maximum area.
It is beer to choose the installaon place with convenient trac, well-equipped power and
internet facilies (e.g., communicaon tower, watchtower and high-rise roof).
7.2.2 Set Dynamic Fire Source
Detecon
To avoid the potenal re damage, you can congure the re detecon funcon for certain areas.
The detail conguraon steps show as below.
Before You Start
Go to
Conguraon → System → Maintenance → VCA Resource Type , select Temperature
Measurement + Perimeter Protecon.
Steps
1.
Go to Conguraon → Local .
2.
Check Locate Highest Temperature Point to display the
posion of highest temperature. Check
Frame Fire Point to frame the re source on live view.
3.
Go to Conguraon → Event → Smart Event , select Dynamic Fire Source Detecon.
4.
Check Enable Dynamic Fire Source
Detecon.
5.
Set the parameters of re detecon.
Fire Source Detecon
Smoking Mode
Detect smoking behavior in the scene.
Dynamic Fire
Detect the dynamic re source in the scene.
Sensivity
The sensivity of re detecon. The bigger the value is, more easily the re source can be
detected, and the false rate is higher.
Alarm Interval
Set the alarm interval between two alarms.
Picture Quality