Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/10933994-ds-2td1117-6-pa/bg3b.png)
Steps
1.
Go to Conguraon → Temperature Measurement & Fire Prevenon → Basic Sengs , check
Enable Temperature Measurement.
2.
Refer to
Set Thermography Parameters to set the parameters.
3.
Go to
Conguraon → Temperature Measurement & Fire Prevenon → Advanced Sengs ,
select Expert.
4.
Select and enable the temperature measurement rules. Please refer to
Set Thermography Rule
for seng the rule.
5.
Oponal: Click Area's Temperature Comparison to set the alarm rules and the temperature.
6.
Click Save.
The maximum temperature and thermography rules will be displayed on the live view.
Note
Go to Image → VCA Rules Display to adjust the font size and the temperature color of normal,
alarm and pre-alarm.
7.
Enable the scan funcon of device, such as linear scan to monitor the scene.
Set Thermography Rule
Steps
1.
Customize the rule name.
2.
Select the rule type to Point, Line, or Area. Then draw a point, line, or area on the interface
where the
posion to be measured.
Point
Please refer to Point Thermography for detailed conguraon.
Line Please refer to Line Thermography for detailed conguraon.
Area Please refer to Area Thermography for detailed conguraon.
3.
Congure the temperature measurement parameters.
Emissivity
Set the emissivity of the target. The emissivity of the surface of a material is its eecveness
in eming energy as thermal radiaon. Dierent objects have dierent emissivity. Refer to
Common Material Emissivity Reference to search for the target emissivity.
Distance
The distance between the target and the device.
Reecve Temperature
If there is any object with high emissivity in the scene, check and set the reecve
temperature to correct the temperature. The reecve temperature should be set the same
as the temperature of the high emissivity object.
4.
Click and set the Alarm Rule.
Alarm Temperature and Pre-Alarm Temperature
Thermal Network Camera User Manual