Installation instructions
Step 8. Convert to lp gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas.
This Dacor gas range can be converted to use LP gas.
(Contact a qualied service technician.)
The conversion process should only be performed by a qualied LP gas installer.
Conversion instructions and LP orices will be supplied with the LP conversion kit.
The conversion to LP requires all burner orices to be changed (6 surface burners
and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orices must be left with the consumer, including the instructions and
retrot sizes and orice indication.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location BTU Rate Orice Size [mm]
LF 16,500 In 0.46 / Out 0.78*2
LR 14,500 In 0.46 / Out 0.74*2
RF 16,500 In 0.46 / Out 0.78*2
RR 14,500 In 0.46 / Out 0.74*2
CF 14,500 1.12
CR 14,500 1.12
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location BTU Rate Orice Size [mm]
LF 22,000 In 0.85 / Out 1.40*2
LR 16,000 In 0.70 / Out 1.17*2
RF 22,000 In 0.85 / Out 1.40*2
RR 16,000 In 0.70 / Out 1.17*2
CF 16,000 1.78
CR 16,000 1.78
WARNING
Do not exceed 25 ft-lbs of torque when making gas line connections.
Overtightening may crack the pressure regulator resulting in gas leak.
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Pressure
Regulator
Adapter
Flex Connector
(6-ft max.)
Adapter
Gas Shut-Off Valve
0.5 in or 0.75 in Gas Pipe
Tubing Line to Cooktop
Control Manifold
Gas Flow into Range
NOTE
• If your area requires a rigid pipe hookup, contact a qualied installer, service
agency, or gas supplier.
• The gas shut-off valve should be installed in an accessible location in the gas
piping, external to the appliance, for the purpose of turning on or shutting off
the gas to the appliance.
Install_DOP36T86DLS_DG68-01106G-00_EN+MES+CFR.indb 25Install_DOP36T86DLS_DG68-01106G-00_EN+MES+CFR.indb 25 2023-02-28 오전 10:19:082023-02-28 오전 10:19:08