Installation
75
EN
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
valve rod clockwise all the way.
Lubricating the gas valves
Over time the gas valves can become
difficult to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Dimensions
Position of gas and electrical connections.
Burner and nozzle characteristics table
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new
type of gas. The label is inserted
inside the nozzle pack (where
fitted).
Lubrication of the gas valves be
performed by a specialised
technician.
A48
B738
C124
D97
NG 1.0 kPa AUX SR R DUAL int + ext
Nominal gas consumption (MJ/h)
3.9 7.5 12 15.2
Injector (1/100)
90 120 155 80 + 165
NG 2.75 kPa AUX SR R DUAL int. + ext.
Nominal gas consumption (MJ/h)
3.9 6.3 10.8 15.2
Injector (1/100)
54 68 88 46 + 94