23. Install strain relief
Install the metallic strain relief provided in this kit (Straight:
Whirlpool Part Number 4317824, 90°: Whirlpool Part Number
W10278923RP). Make sure screw heads are facing to the
left when tightening conduit nut. Strain relief is provided with
the power cord kit.
24. Power cord route cord into terminal box
Route cord so that it does not touch dishwasher motor or
lower part of dishwasher tub. Pull cord through strain relief in
terminal box.
NOTE: A maximum of 2 power cord supply conductors (12
AWG largest size) plus 1 grounding conductor are permitted
in the terminal box.
WARNING
Electrical Shock Hazard
Electrically ground appliance.
Connect ground wire to green ground connector in
terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
25. Power cord connect ground wire
A
A. Ground wire
Remove the ground connector screw and place it through the
ring terminal of the green ground wire of power cord.
Reattach and tighten the ground connector screw.
26. Power cord connect remaining wires
Select twist-on wire connectors of the proper size provided in
this kit (Straight: Whirlpool Part Number 4317824, 90°:
Whirlpool Part Number W10278923RP) . Connect wires,
black to black and white to white, using the twist-on wire
connectors.
NOTE: Do not pre-twist stranded wire. Twist on wire
connector. Gently tug on wires to be sure both are secured.