Before You Start
Go to VCA and select the applicaon. Select Smart Event and click Next to enable the funcon.
For the device supporng HEOP, go to VCA to import and enable Smart Event.
Steps
1.
Go to VCA → Set Applicaon → Smart Event → Region Exing Detecon .
2.
Check Enable.
3.
Click Add to add a rule and set a detecon area.
1) Draw a detecon area. Click , click on the live view to specify the vertexes and draw the
boundaries of the detecon area, and right click to complete drawing.
2) Set the minimum size and the maximum size for the target to improve detecon accuracy.
Only targets whose size are between the maximum size and the minimum size trigger the
detecon. Click and , then drag the mouse in the live view to draw the minimum and
maximum target size.
3) Oponal: Click to delete all the seng areas.
4.
Set parameters.
Detecon Target
This funcon allows alarm triggering by specied selected target types. If the detecon target
is not selected, all the detected targets will be reported.
Note
This funcon is only available for certain device models under certain sengs. Please refer to
the actual sengs.
Sensivity
It stands for the percentage of the body part of an acceptable target that goes across the
predened region. Sensivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predened region. ST stands for the complete target body. The higher the value of
sensivity is, the more easily the alarm can be triggered.
Target Validity
If you set a higher validity, the required target features should be more obvious, and the
alarm accuracy would be higher. The target with less obvious features would be missing.