User Manual for the Fluke 190-062/AM ScopeMeter Oscilloscope, 2 Channel, 60 MHz - Page 34

For 190-062/AM.

PDF File Manual, 152 pages, Read Online | Download pdf file

190-062/AM photo
Loading ...
Loading ...
Loading ...
ScopeMeter® Test Tool 190 Series II
Users Manual
22
Figure 9. Smoothing a Waveform
Using Persistence, Envelope and Dot-Join to
Display Waveforms
You can use Persistence to observe dynamic signals. See
Figure 10.
1
Display the SCOPE key labels.
2
Open the WAVEFORM OPTIONS menu.
3
ENTER
Jump to Waveform: and open the
Persistence... menu.
4
ENTER
Select Digital Persistence: Short,
Medium, Long or Infinite to observe
dynamic waveforms like on an analog
oscilloscope.
Select Digital Persistence: Off,
Display: Envelope to see the upper
and lower boundaries of dynamic
waveforms (envelope mode).