FLUKE 190-062/AM ScopeMeter Oscilloscope, 2 Channel, 60 MHz

User Manual for the Fluke 190-062/AM ScopeMeter Oscilloscope, 2 Channel, 60 MHz - Page 130

For 190-062/AM.

PDF File Manual, 152 pages, Read Online | Download pdf file

190-062/AM photo
Loading ...
Loading ...
Loading ...
ScopeMeter® Test Tool 190 Series II
Users Manual
118
Amperes (AMP)
With Optional Current Probe or Current Shunt
Ranges ............................. same as VDC, VAC, VAC+DC
Probe Sensitivity ................. 100 µV/A, 1 mV/A, 10 mV/A,
100 mV/A, 400 mV/A, 1 V/A, 10 V/A, and 100 V/A
Accuracy ........................... same as VDC, VAC, VAC+DC
(add current probe or current shunt accuracy)
Peak
Modes .................... Max peak, Min peak, or peak-to-peak
Maximum Voltage
with 10:1 probe .................................................. 1000 V
direct (1:1) ............................................................ 300 V
Maximum Resolution
with 10:1 probe ................................................... 10 mV
direct (1:1) ............................................................. 1 mV
Full Scale Reading .......................................... 800 counts
Accuracy
Max peak or Min peak ................................ ±0.2 division
Peak-to-peak.............................................. ±0.4 division
Frequency (Hz)
Range ...................................... 1.000 Hz to full bandwidth
Full Scale Reading .......................................... 999 counts
Accuracy
1 Hz to full bandwidth ...................... ±(0.5 % +2 counts)
(4 s/div to 10 ns/div and 10 periods on the screen).
Duty Cycle (DUTY)
Range ..................................................... 4.0 % to 98.0 %
Resolution ............................. 0.1 % (when period > 2 div)
Full Scale Reading ................. 999 counts (3-digit display)
Accuracy (logic or pulse) .................... ±(0.5 % +2 counts)
Pulse Width (PULSE)
Resolution (with GLITCH off) ........................ 1/100 division
Full Scale Reading .......................................... 999 counts
Accuracy
1 Hz to full bandwidth ...................... ±(0.5 % +2 counts)
Vpwm
Purpose ................. to measure on pulse width modulated
signals, like motor drive inverter outputs
Principle ......... readings show the effective voltage based
on the average value of samples over a
whole number of periods of the fundamental
frequency
Accuracy ............................ as Vrms for sinewave signals
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com
Loading ...
Loading ...