2. Adjusting the Temperature Setpoint
The temperature setpoint is the value for the average cabinet temperature. The
temperature differential for the compressor to turn on and off is ±3°F (±1.7°C) of the
temperature setpoint. For example, for a refrigerator temperature setpoint of 36°F (2°C),
the compressor comes on at 39°F (3.7°C), and the compressor goes off at 33°F (0.3°C).
If necessary, adjust the temperature setpoint temperature as follows:
1) To change the temperature setpoint, press and release the up or down button.
The current temperature setpoint appears. Press the up or down button until the
desired value is displayed. After a few seconds, the display returns to the current
cabinet temperature and the temperature setpoint is saved. NOTICE! Do not adjust
the temperature setpoint more than 2°F (1°C) at a time. Allow the temperature to
stabilize for a minimum of 8hours before making further temperature setpoint
adjustments.
• For refrigerators, the temperature setpoint is adjustable between 31°F and 52°F
(-0.5°C and 11°C). The factory default is 38°F (3°C).
• For freezers, the temperature setpoint is adjustable between -10°F and +12°F (-24°C
and -11°C). The factory default is -2°F (-19°C).
3. Changing the Temperature Display Scale (°F or °C)
To change the temperature display scale, press either the up or down button for
5seconds. The factory default is °F.
4. Light Control for Glass Door Models
Glass door models feature lights that are controlled by the Standby/Light control button
located on the control module. See Fig. 73. Press the standby/light button quickly to turn
the light on or off.
Fig. 73
Standby and Light Control for
Glass Door Models
Front Panel
Control Module
Control Panel