Broan V230H75RS vänEE AI Series HRV 231 CFM 78% SRE with Virtuo Air Technology Side ports

Installation Guide - Page 7

For V230H75RS.

PDF File Manual, 52 pages, Read Online | Download pdf file

V230H75RS photo
Loading ...
Loading ...
Loading ...
7
2.2.3 simplified insTAllATion (T-4) (THis confiGurATion does noT Allow recirculATion mode To operATe.)
The central forced-air system must be synchronized with the unit since fresh air evacuation and distribution
come from the same section. The central forced-air system must operate to avoid fresh air to be directly
drawn by the evacuation, which would reduce signicantly fresh air supply to the building. See Section 3.3
for ducting.
CAUTION
Duct connection to the central forced-air system can be regulated by some codes and standards. It is your
responsibility to consider and comply with your local requirements to avoid any non-compliance.
WARNING
!
VH0168
Fresh air and exhaust air ow through the central forced-air
system ducts, which simplies the installation.
The use of bathroom fans and a range hood is suggested to
exhaust stale air.
Stale air from building:
Connect the stale air intake port of the unit to the central forced-
air system return duct at least 3 feet ahead of the fresh air
distribution from the unit.
freSh air to building:
Connect the fresh air distribution duct of the unit to the central
forced-air system return duct at least 10 feet away from the
central forced-air system (A+B)*.
* This 10-ft. distance applies only in areas where the outside
temperature falls below the freezing point 0°C (32°F).
VH0167
C
B
A
A+b= min 10’
c=3’
AlTernATe insTAllATion (T-5) (THis confiGurATion does noT Allow
recirculATion mode To operATe.)
Unit should be synchronized with central forced-air system
operation to avoid condensation and mold growth in central
forced-air system distribution ducting if cooling mode of central
forced-air system is used.
Fresh air
to building
Stale air from
building
Stale air to
outdoors
Fresh air from
outdoors
This conguration is not recommended with high velocity
central forced-air system. High pressures produced by
these systems could affect unit proper operation and
generate errors.
CAUTION
NOTE: For this type of conguration, the T-5 option must be
selected on the LCD screen when auto-balancing the unit.
Stale air to
outdoors
Fresh air from
outdoors
Fresh air to
building
Stale air from
building
NOTE: For this type of conguration, the T-4 option must be
selected on the LCD screen when auto-balancing the unit.
VH0166
AlTernATe insTAllATion (T-3) (THis confiGurATion Allows recirculATion
mode To operATe.)
Unit should be synchronized with central forced-air system
operation to avoid condensation and mold growth in central forced-
air system distribution ducting if cooling mode of central forced-air
system is used.
This conguration is not recommended with high velocity
central forced-air system. High pressures produced by these
systems could affect unit proper operation and generate
errors.
CAUTION
NOTE: For this type of conguration, the T-3 option must be
selected on the LCD screen when auto-balancing the unit.
Stale air from
bathroom
Fresh air to
building
Stale air to
outdoors
Fresh air from
outdoors