Electrical Connection
Electrical Requirements
Check your local codes regarding this unit. This cooktop is supplied with a 3-wire, A.C. 208V/240V, 60 HZ electrical system. A white
(neutral) is not needed for this unit. See next section for grounding instructions. It should be fused separately.
Refer to the speci cations chart for kilowatt rating and recommended amperage. House wiring and fusing must comply with local
codes. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.
When making the wire connections, use the entire length of the conduit provided (4 feet). The conduit must not be cut. Connect
the red and black leads from the unit conduit to the corresponding leads in the junction box. The bare ground wire in the conduit
is connected to the unit frame. When connecting to a 3-conductor branch circuit, connect the bare ground connector lead of the
unit to the branch circuit ground (bare wire or green in color). Cap any unused wires, do not splice the Neutral and Earth from the
supply. Do not connect the white wire (neutral) to ground, doing so will cause the induction units not to operate properly.
WARNING
BURN HAZARD
The use of cabinets for storage
above the appliance may result
in potential burn hazard. Combustible items
may ignite, metallic items may become hot
and cause burns. If a cabinet storage is to be
provided the risk can be reduced by installing
a range hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom
of the cabinets.
WARNING
The electrical power to the breaker box to the junction box
must be shut o while line connections are being made.
Failure to do so could result in serious injury or death.
WARNING
FIRE AND ELECTRICAL SHOCK HAZARD
DO NOT use an extension cord with this
appliance. Such use may result in  re, electrical
shock, or other personal injury.
DO NOT remove permanently a xed labels, warnings, or plates from product. This may void the warranty.
Please observe all local and national codes and ordinances. Installation must conform with local codes and National Fuel Gas
Code ANSIZ233.1/NFPA-54–latest edition.
Please ensure that this product is properly grounded.
Installation should only be completed by a qualifed technician
The installer must leave these instructions with the consumer who should retain for local inspectors use and for future
reference.
Installation must conform with local codes or, in the absence of codes, the National Electrical Code, ANSI/NFPA 70-latest edition.
In Canada: Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local
codes.
1
2
Ground
Green
Black
Red
Lower cooktop into cutout. Connect the red and black leads from the unit conduit to the
corresponding leads in the junction box.