Amana WVU17UC0JB 30" Range Hood with Full-Width Grease Filters

Owner's Manual - Page 8

For WVU17UC0JB.

PDF File Manual, 24 pages, Read Online | Download pdf file

WVU17UC0JB photo
Loading ...
Loading ...
Loading ...
8
6. Mark hole locations
Lift the range hood into place and insert the mounting bracket
tabs through the slots in the back of the range hood.
Hold the range hood rmly in place with one hand and bend
each mounting tab (A) upward approximately 90°.
Mark the hole at the power supply knockout (B).
OPTIONAL: Mark the hole in each mounting tab.
Remove the range hood and set it aside.
7. Mark and cut vent opening
7" (17.8 cm) Round Vent System
Using the 7" (17.8 cm) round vent mounting plate, draw the
vent opening outline on the underside of the cabinet:
- Place the vent mounting plate on the bottom of the
cabinet. Position the edge of the plate with the widest
distance (A) between the hole and edge of the mounting
plate against the wall. Position the side edges of the
mounting plate between the dots marked previously
IMPORTANT: The widest edge (A) of the vent
mounting plate must be positioned against the wall.
- Trace the 7" (17.8 cm) vent opening (solid line) on the
cabinet bottom.
Using a jigsaw or keyhole saw, cut the vent opening
1" (2.5cm) larger than the 7" (17.8 cm) hole traced
(dashedline).
8. Drill electrical opening
Using a 1
1
/
4
" (3 cm) drill bit, drill the hole in the dot marked
previously at the electrical strain relief.
OPTIONAL: Using a 1/8" (3 mm) drill bit, drill pilot holes for the
dots marked previously at each mounting tab at an approximate
45° angle in an upward direction.
9. Prepare Range Hood Vents and
Mounting Tabs.
Install Strain Relief
Install a UL listed/CSA approved 1/2" (13 mm) strain
relief(A).
Mounting Tabs
Start a #8-18 x 5/8" (4.2 x 16 mm) truss-head screw into the
mounting tab (F) on each side of the range hood as shown
in the inset. Insert the screws approximately 2 turns into the
mounting tab holes.
Non-vent (Recirculating) Installations
Using a #2 Phillips screwdriver remove the 2 screws and
remove the top, front rectangular vent cover (E). Go to
Step12.
7" (17.8 cm) Round Vent Installations
Remove both top knockouts (C and D).
A
B
1"
A
(2.5 cm)
A
B
C
D
E
x2
F
Loading ...
Loading ...
Loading ...