FLUKE 772 Milliamp Process Clamp Meter, Dual Backlit Display

User Manual for the Fluke 772 Milliamp Process Clamp Meter, Dual Backlit Display - Page 10

For 772.

PDF File Manual, 23 pages, Read Online | Download pdf file

772 photo
Loading ...
Loading ...
Loading ...
Milliamp Process Clamp Meter
General Specifications
5
DC Voltage Source (773)
Range........................................ 0-10 V
Resolution.................................. 0.01 V
Accuracy....................................0.2 % + 2 counts
mA Drive.................................... 2 mA max all conditions
mA DC IN/OUT (773)
Sourcing range .......................... 0-24 mA
Sourcing resolution.................... 0.01 mA
Sourcing accuracy ..................... 0.2 % + 2 counts
Measurement range ..................0-24 mA
Measurement resolution 0.01 mA
Measurement accuracy ............. 1 % FS
Scaled mA DC Current Output to mA Current Input from the Jaw (773)
Range........................................ 0-24 mA
Resolution.................................. 0.01 mA
Accuracy....................................1 % FS
General Specifications
Response speed........................... 2 times per second
DC Loop Power ............................ 24 V
Influence of Earth’s Field .............. < 0.20 mA
Batteries ....................................... 4 1.5 V, Alkaline, IEC LR6
Working hours ..............................12 hours @ 12 mA sourced into 500 Ω
Mechanical Specifications
Size (H X W X L) ......................... 43.7 mm x 70 mm x 246.2 mm
Weight .......................................... 410 g
Environmental Specifications
Operating Temperature .................. -10 ~ 50 °C
Storage Temperature...................... -25 ~ 60 °C
Operating Humidity......................... <90 % RH @ <30 °C ;<75 % RH @ 30 ~ 50 °C
Operating Altitude........................... 0 ~ 2000 m
IP Rating......................................... IP 40
Vibration Requirements .................. Random 2 g, 5 to 500 Hz
Drop Test Requirements............... 1 meter drop test (except the jaw)
EMI, RFI, EMC ............................. Meets all applicable requirements in EN61326-1
Note: For current measurement w/jaw, add 1 mA to specification for
EMC field strengths of 1 V/m up to 3 V/m.
Temperature Coefficients ............... 0.1(/ °C X Specified accuracy for Temperature < 18 °C or > 28 °C)
Standards and Agency Approval Specifications
All products certified to the following:
EN / IEC 61010-1, EN / IEC 61010-2-032
Agency Approvals:
P, ), ;
Other Specifications
Power Requirements ...... .......................................... Four AA batteries, Alkaline, IEC LR6
Automatic Time-out (Power) ...................................... After 15 minutes ±1 minutes
Automatic Time-out (Backlight).................................. After 2 minutes ±10 seconds
Automatic Time-out (Measurement Spotlight) ........... After 2 minutes ±10 seconds
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com
Loading ...
Loading ...
Loading ...