46
AXIS P1346/-E/AXIS P1347/-E - Unit connectors
The following connection diagram gives an example of how to connect an auxiliary device to the network camera.
LED indicators
Note:
Please refer to the product’s Installation Guide for information on the LED indicators for the housing electronics
(fan/heater) and a description of the behavior of the Status LED when using the Focus Assistant.
Function Pin Notes Specifications
GND 1 Ground
3.3 V DC Power 2 Can be used to power auxiliary equipment.
Note: This pin can only
be used as power out.
Max load = 50 mA
Digital Input 3 Connect to GND to activate, or leave floating (unconnected) to
deactivate.
AXIS P1346-E/AXIS P1347-E: Connected to housing electronics at
delivery.
Min. input = -40 V DC
Max. input= +40 V DC
Digital Output 4 Uses an open-drain NFET transistor with the source connected to
GND. If used with an external relay, a diode must be connected in
parallel with the load, for protection against voltage transients.
Max. load =100 mA
Max. voltage = + 40 V DC
LED Color Indication
Network Green Steady for connection to a 100 Mbit/s network. Flashes for network activity.
Amber Steady for connection to 10 Mbit/s network. Flashes for network activity.
Unlit No network connection.
Status Green Steady green for normal operation.
Note: The Status LED can be configured to be unlit during normal operation, or to
flash only when the camera is accessed. To configure, go to Setup > System
Options > LED settings. See the online help files for more information.
Amber Steady during startup, during reset to factory default or when restoring settings.
Red Slow flash for failed upgrade.
Power Green Normal operation.
Amber Flashes green/amber during firmware upgrade.