21INSTALLATION
ENGLISH
insulation from each wire. Bend the ends of
the three wires into a hook shape.
2 Remove the terminal block access cover on
the upper back of the appliance.
3 Install UL-listed strain relief into the power
cord through-hole.
4 Thread the 3-wire, #10 AWG minimum copper
conductor power cable prepared in step 1
through the strain relief.
a Terminal block
b UL-listed strain relief
c UL-listed 3-wire power cord
5 Attach the two hot leads (black and red) of the
power cord to the outer terminal block
screws.
6 Attach the neutral (white) wire to the center
terminal block screw.
7 Connect the external ground (if required by
local codes) to the green ground screw.
8 Tighten all screws securely.
9 Reinstall the terminal block access cover.
a Hot lead (black and red)
b Neutral wire (white)
c External ground wire (if required by local
codes)
d Wire from the appliance harness
e Ground screw (green)
Connecting the Drain Hose
WARNING
The drain hose should always be properly
secured. Failure to properly secure the drain
hose can result in flooding and property
damage.
NOTE
The drain must be installed in accordance with
any applicable local codes and regulations.
Make sure that the drain hose is not stretched,
pinched, crushed, or kinked.
How to Connect the Drain Hose
1 Insert the hose clamp a onto the drain hose
of the dryer.
1’’ (2.5 cm)